  • !SURFEX_LIC Copyright 1994-2014 Meteo-France 
    !SURFEX_LIC This is part of the SURFEX software governed by the CeCILL-C  licence
    !SURFEX_LIC version 1. See LICENSE, CeCILL-C_V1-en.txt and CeCILL-C_V1-fr.txt
    !SURFEX_LIC for details. version 1.
    
    !   ##########################################################################
        SUBROUTINE FLOOR_LAYER_E_BUDGET(PT_FLOOR, PTSTEP, PHC_FLOOR, PTC_FLOOR, PD_FLOOR, &
                                        PFLX_BLD_FLOOR, PDQS_FLOOR, PIMB_FLOOR,           &
                                        PF_FLOOR_MASS, PF_FLOOR_WALL, PF_FLOOR_WIN,       &
                                        PF_FLOOR_ROOF, PRADHT_IN,           &
                                        PTS_MASS, PRAD_WALL_FLOOR, PRAD_ROOF_FLOOR,       &
                                        PRAD_WIN_FLOOR, PLOAD_FLOOR, PTI_BLD,             &
                                        PRAD_FLOOR_MASS, PCONV_FLOOR_BLD                  )
    !   ##########################################################################
    !
    !!****  *FLOOR_LAYER_E_BUDGET*  
    !!
    !!    PURPOSE
    !!    -------
    !
    !     Computes the evoultion of building floor temperatures
    !         
    !     
    !!**  METHOD
    !     ------
    !
    !    6 : equations for evolution of Ts_floor 
    !        *************************************************************
    !
    !     dTf_k(t) / dt = 1/(df_k*Cf_k) * (- 2*Kf_k-1*(Tf_k-Tf_k-1)/(df_k-1 +df_k) 
    !                                      - 2*Kf_k  *(Tf_k-Tf_k+1)/(df_k+1 +df_k) )
    !
    !     dTf_1(t) / dt = 1/(df_1*Cf_1) * (- 2*Kw_1*(Tw_1-Tw_2)/(dw_1 +dw_2))
    !
    !       with
    !
    !   K*_k  = (d*_k+ d*_k+1)/(d*_k/k*_k+ d*_k+1/k*_k+1)
    !
    !
    ! The system is implicited (or semi-implicited).
    !
    ! ZIMPL=1    ---> implicit system
    ! ZIMPL=0.5  ---> semi-implicit system
    ! ZIMPL=0    ---> explicit system
    !
    !
    !
    !
    !!    EXTERNAL
    !!    --------
    !!
    !!
    !!    IMPLICIT ARGUMENTS
    !!    ------------------
    !!
    !!    MODD_CST
    !!
    !!      
    !!    REFERENCE
    !!    ---------
    !!
    !!      
    !!    AUTHOR
    !!    ------
    !!
    !!	G. Pigeon           * Meteo-France *
    !!
    !!    MODIFICATIONS
    !!    -------------
    !!      Original    15/04/09 
    !!      G. Pigeon      08/10 computation of residual of energy balance 
    !!                           modification of the limit condition for
    !!                           the deep temp. from the deep road temp.
    !!                           to zero flux condition. idem for sfce T
    !!      G. Pigeon      11/11 split in 2 for floor and mass to be flux conservative
    !!      G. Pigeon      09/12 modif of conv. coef + implicitation of the exchange
    !-------------------------------------------------------------------------------
    !
    !*       0.     DECLARATIONS
    !               ------------
    !
    USE MODI_LAYER_E_BUDGET_GET_COEF
    USE MODI_LAYER_E_BUDGET
    USE MODE_CONV_DOE
    !
    USE YOMHOOK   ,ONLY : LHOOK,   DR_HOOK
    USE PARKIND1  ,ONLY : JPRB
    !
    IMPLICIT NONE
    !
    !*      0.1    declarations of arguments
    !
    REAL, DIMENSION(:,:), INTENT(INOUT) :: PT_FLOOR     ! floor layers temperatures
    REAL,                 INTENT(IN)    :: PTSTEP       ! time step
    REAL, DIMENSION(:,:), INTENT(IN)    :: PHC_FLOOR    ! heat capacity for road layers
    REAL, DIMENSION(:,:), INTENT(IN)    :: PTC_FLOOR    ! thermal conductivity for 
                                                        !road layers
    REAL, DIMENSION(:,:), INTENT(IN)  :: PD_FLOOR       ! depth of road layers
    REAL, DIMENSION(:),   INTENT(OUT)  :: PFLX_BLD_FLOOR !flux from building to floor
    REAL, DIMENSION(:),   INTENT(OUT) :: PDQS_FLOOR !heat storage inside the floor
    REAL, DIMENSION(:),   INTENT(OUT) :: PIMB_FLOOR !floor energy residual imbalance for verification
    REAL, DIMENSION(:), INTENT(IN)    :: PF_FLOOR_MASS  ! View factor floor-mass
    REAL, DIMENSION(:), INTENT(IN)    :: PF_FLOOR_WALL  ! View factor floor-wall
    REAL, DIMENSION(:), INTENT(IN)    :: PF_FLOOR_WIN   ! View factor floor-window
    REAL, DIMENSION(:), INTENT(IN)    :: PF_FLOOR_ROOF  ! View factor floor-roof
    REAL, DIMENSION(:), INTENT(IN)    :: PRADHT_IN      ! Indoor radiant heat transfer coefficient
                                                        ! [W K-1 m-2]
    REAL, DIMENSION(:), INTENT(IN)    :: PTS_MASS  ! surf. mass temp. (contact with bld air)
    REAL, DIMENSION(:), INTENT(IN)    :: PRAD_ROOF_FLOOR ! rad. fluxes from roof to floor[W m-2(roof)]
    REAL, DIMENSION(:), INTENT(IN)    :: PRAD_WALL_FLOOR ! rad. fluxes from wall to floor[W m-2(wall)]
    REAL, DIMENSION(:), INTENT(IN)    :: PRAD_WIN_FLOOR  ! rad. fluxes from win to floor[W m-2(win)]
    REAL, DIMENSION(:), INTENT(IN)    :: PTI_BLD   ! indoor air temp.
    REAL, DIMENSION(:), INTENT(IN)    :: PLOAD_FLOOR ! solar and internal load to the floor
    REAL, DIMENSION(:), INTENT(OUT)   :: PRAD_FLOOR_MASS  ! rad. fluxes from floor to mass [W m-2(floor)]
    REAL, DIMENSION(:), INTENT(OUT)   :: PCONV_FLOOR_BLD  ! conv. fluxes from floor to bld [W m-2(floor)]
    !
    !*      0.2    declarations of local variables
    !
    !
    REAL :: ZIMPL=1.0      ! implicit coefficient
    REAL :: ZEXPL=0.0      ! explicit coefficient
    !
    REAL, DIMENSION(SIZE(PT_FLOOR,1),SIZE(PT_FLOOR,2)) :: ZA,& ! lower diag.
                                                          ZB,& ! main  diag.
                                                          ZC,& ! upper diag.
                                                          ZY   ! r.h.s.
    !
    REAL, DIMENSION(SIZE(PT_FLOOR,1)) :: ZTS_FLOOR ! surf. floor temp.  used for rad. exchanges
    REAL, DIMENSION(SIZE(PT_FLOOR,1)) :: ZTS_FLOOR_CONV ! surf. floor temp. used for conv exchanges
                                                   ! used during calculation
    REAL, DIMENSION(SIZE(PT_FLOOR,1)) :: ZCHTC_IN_FLOOR   ! Indoor floor convec heat transfer coefficient
                                                        ! [W K-1 m-2(bld)]
    
    REAL(KIND=JPRB) :: ZHOOK_HANDLE
    INTEGER :: JJ
    !-------------------------------------------------------------------------------
    IF (LHOOK) CALL DR_HOOK('FLOOR_LAYER_E_BUDGET',0,ZHOOK_HANDLE)
    !
    ! *Convection heat transfer coefficients [W m-2 K-1]
    !  From EP Engineering Reference
    ZCHTC_IN_FLOOR(:) = CHTC_UP_DOE(PT_FLOOR(:,1), PTI_BLD(:))
    DO JJ=1,SIZE(ZCHTC_IN_FLOOR)
       ZCHTC_IN_FLOOR(JJ) = MAX(1., ZCHTC_IN_FLOOR(JJ))
    ENDDO
    
    
    !
     CALL LAYER_E_BUDGET_GET_COEF( PT_FLOOR, PTSTEP, ZIMPL, PHC_FLOOR, PTC_FLOOR, PD_FLOOR, &
                                  ZA, ZB, ZC, ZY )
    !
    ZTS_FLOOR(:) = PT_FLOOR(:,1) 
    
    ZB(:,1) = ZB(:,1) + ZIMPL * &
       (ZCHTC_IN_FLOOR(:)*4./3. + PRADHT_IN(:) * PF_FLOOR_MASS(:))
    
    
    ZY(:,1) = ZY(:,1)  &
       + ZCHTC_IN_FLOOR(:) * (PTI_BLD(:) - 1./3. * PT_FLOOR(:, 1) * (4* ZEXPL -1))  &
       + PF_FLOOR_WIN  (:) * PRAD_WIN_FLOOR(:)                    &
       + PF_FLOOR_WALL (:) * PRAD_WALL_FLOOR(:)                   &
       + PF_FLOOR_ROOF (:) * PRAD_ROOF_FLOOR(:)                   &
       + PRADHT_IN(:) * PF_FLOOR_MASS (:) * (PTS_MASS(:) - ZEXPL * PT_FLOOR(:,1))  &
       + PLOAD_FLOOR(:)
    !
     CALL LAYER_E_BUDGET( PT_FLOOR, PTSTEP, ZIMPL, PHC_FLOOR, PTC_FLOOR, PD_FLOOR, &
                         ZA, ZB, ZC, ZY, PDQS_FLOOR )
    !
    !*      floor surface temperature used in the implicit formulation
    !       ----------------------------------------------------------
    ZTS_FLOOR_CONV(:) = 4./3. * ZIMPL * PT_FLOOR(:,1) + 1./3. * ZTS_FLOOR(:) * (4 * ZEXPL - 1.)
    ZTS_FLOOR(:) = ZEXPL * ZTS_FLOOR(:) + ZIMPL * PT_FLOOR(:,1)
    !
    !*      fluxes with mass and indoor air
    !       ----------------------------------------------------------
    PRAD_FLOOR_MASS(:) = PRADHT_IN(:)    * (ZTS_FLOOR(:) - PTS_MASS(:))
    PCONV_FLOOR_BLD(:) = ZCHTC_IN_FLOOR(:) * (ZTS_FLOOR_CONV(:) - PTI_BLD (:))
    !
    !*     Flux between floor and indoor surfaces and air
    !       ------------------------------------------------
    PFLX_BLD_FLOOR(:) = - PCONV_FLOOR_BLD(:)  &
           + PF_FLOOR_WIN  (:) * PRAD_WIN_FLOOR(:)  &
           + PF_FLOOR_WALL (:) * PRAD_WALL_FLOOR(:) &
           + PF_FLOOR_ROOF (:) * PRAD_ROOF_FLOOR(:) &
           + PRADHT_IN(:) * PF_FLOOR_MASS(:) * (PTS_MASS (:)  - ZTS_FLOOR(:)) &
           + PLOAD_FLOOR(:)
    !
    !*     Floor residual energy imbalance for verification
    !       ------------------------------------------------
    PIMB_FLOOR(:) = PFLX_BLD_FLOOR(:) - PDQS_FLOOR(:)
    !
    IF (LHOOK) CALL DR_HOOK('FLOOR_LAYER_E_BUDGET',1,ZHOOK_HANDLE)
    !-------------------------------------------------------------------------------
    END SUBROUTINE FLOOR_LAYER_E_BUDGET