Newer
Older
!SFX_LIC Copyright 1994-2014 CNRS, Meteo-France and Universite Paul Sabatier
!SFX_LIC This is part of the SURFEX software governed by the CeCILL-C licence
!SFX_LIC version 1. See LICENSE, CeCILL-C_V1-en.txt and CeCILL-C_V1-fr.txt
!SFX_LIC for details. version 1.
SUBROUTINE INI_DATA_PARAM_TEB(HPROGRAM, BDD, DTT, KTYPE, PFLOOR_HEIGHT, &
PCAP_SYS_HEAT, PCAP_SYS_RAT, PT_ADP, PM_SYS_RAT, &
PT_SIZE_MAX, PT_SIZE_MIN, PROUGH_ROOF, PROUGH_WALL, &
PALB_ROOF, PEMIS_ROOF, PHC_ROOF, PTC_ROOF, PD_ROOF, &
PALB_WALL, PEMIS_WALL, PHC_WALL, PTC_WALL, PD_WALL, &
NISOROOFPOS, NISOWALLPOS, PALB_ROAD, PEMIS_ROAD, PHC_ROAD, PTC_ROAD, PD_ROAD, &
PHC_FLOOR, PTC_FLOOR, PD_FLOOR, PISMASS, PHC_MASS, PTC_MASS, &
PD_MASS, PN50,PGR,PU_WIN,PSHGC,PSHGC_SH,PSHADEARCHI, &
PISMECH,PMECHRATE,PGREENROOF, &
PEMIS_PANEL,PALB_PANEL,PEFF_PANEL, &
PFRAC_PANEL, PTHEAT_OCCD,PTHEAT_OCCN,PTHEAT_VCDD,PTHEAT_VCDN, &
PTHEAT_VCLD,PFRACOMP,PTCOOL_OCCD,PTCOOL_OCCN,PTCOOL_VCDD,PTCOOL_VCDN,&
PTCOOL_VCLD,PF_WATER_COND,PCOP_RAT,PHR_TARGET,PQIN,PQIN_FRAD, &
PQIN_FLAT,PMODQIN_VCD,PMODQIN_VLD,PMODQIN_NIG,PHOTWAT,PNATVENT,PFVSUM,PFVNIG, &
PTDESV,PFVVAC,PFOPEN,PFSSUM,PFSNIG,PFSVAC,PWIN_SW_MAX,PDAYWBEG_SCHED, &
PHOURBEG_SCHED,PBEG_HOLIDAY,PEND_HOLIDAY,PMOD_HOLIDAY,PPROBOCC,PF_WASTE_CAN)
! #########################
!
!!
!! PURPOSE
!! -------
!!
!! METHOD
!! ------
!!
!!
!! EXTERNAL
!! --------
!!
!! IMPLICIT ARGUMENTS
!! ------------------
!!
!! REFERENCE
!! ---------
!!
!! AUTHOR
!! ------
!!
!! S. Faroux & V. Masson Meteo-France
!!
!! MODIFICATION
!! ------------
!!
!! Original 05/2012 from INI_DATA_PARAM_TEB, separates urban parameters
!! modified 08/2012 add PROUGH_ROOF, PROUGH_WALL
!! R. Schoetter 11/2015 Major changes in order to read MApUCE data
!----------------------------------------------------------------------------
!
!* 0. DECLARATION
! -----------
!
USE MODD_BLD_DESCRIPTION_n, ONLY : BLD_DESC_t
USE MODD_DATA_TEB_n, ONLY : DATA_TEB_t
USE MODD_CSTS, ONLY : XSURF_EPSILON
USE MODI_GET_LUOUT
!
USE YOMHOOK ,ONLY : LHOOK, DR_HOOK
USE PARKIND1 ,ONLY : JPRB
!
IMPLICIT NONE
!
!* 0.1 Declaration of arguments
! ------------------------
!
TYPE(DATA_TEB_t), INTENT(INOUT) :: DTT
INTEGER, DIMENSION(:), INTENT(INOUT) :: KTYPE
CHARACTER(LEN=6), INTENT(IN) :: HPROGRAM ! program calling surf. schemes
!
! Parameters not yet read from tables
!
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PFLOOR_HEIGHT
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PCAP_SYS_HEAT
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PCAP_SYS_RAT
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PT_ADP
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PM_SYS_RAT
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PT_SIZE_MAX
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PT_SIZE_MIN
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PROUGH_ROOF
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PROUGH_WALL
!
! Building architectural characteristics
!
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PALB_ROOF
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PEMIS_ROOF
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PHC_ROOF
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTC_ROOF
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PD_ROOF
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PALB_WALL
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PEMIS_WALL
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PHC_WALL
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTC_WALL
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PD_WALL
INTEGER, DIMENSION(:), INTENT(OUT), OPTIONAL :: NISOROOFPOS
INTEGER, DIMENSION(:), INTENT(OUT), OPTIONAL :: NISOWALLPOS
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PALB_ROAD
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PEMIS_ROAD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PHC_ROAD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTC_ROAD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PD_ROAD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PHC_FLOOR
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTC_FLOOR
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PD_FLOOR
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
REAL, DIMENSION(:) , INTENT(OUT), OPTIONAL :: PISMASS
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PHC_MASS
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTC_MASS
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PD_MASS
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PN50
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PGR
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PU_WIN
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PSHGC
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PSHGC_SH
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PSHADEARCHI
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PISMECH
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PMECHRATE
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PGREENROOF
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PEMIS_PANEL
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PALB_PANEL
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PEFF_PANEL
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PFRAC_PANEL
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PF_WASTE_CAN
!
! Occupant behaviour characteristics
!
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTHEAT_OCCD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTHEAT_OCCN
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTHEAT_VCDD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTHEAT_VCDN
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTHEAT_VCLD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFRACOMP
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTCOOL_OCCD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTCOOL_OCCN
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTCOOL_VCDD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTCOOL_VCDN
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTCOOL_VCLD
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PF_WATER_COND
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PCOP_RAT
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PHR_TARGET
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PQIN
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PQIN_FRAD
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PQIN_FLAT
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PMODQIN_VCD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PMODQIN_VLD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PMODQIN_NIG
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PHOTWAT
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PNATVENT
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFVSUM
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFVNIG
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PTDESV
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFVVAC
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PFOPEN
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFSSUM
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFSNIG
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFSVAC
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PWIN_SW_MAX
REAL, DIMENSION(:,:,:), INTENT(OUT), OPTIONAL :: PBEG_HOLIDAY
REAL, DIMENSION(:,:,:), INTENT(OUT), OPTIONAL :: PEND_HOLIDAY
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PMOD_HOLIDAY
REAL, DIMENSION(:,:,:), INTENT(OUT), OPTIONAL :: PDAYWBEG_SCHED
REAL, DIMENSION(:,:,:), INTENT(OUT), OPTIONAL :: PHOURBEG_SCHED
REAL, DIMENSION(:,:,:), INTENT(OUT), OPTIONAL :: PPROBOCC
!
!* 0.2 Declaration of local variables
! ------------------------------
!
INTEGER, DIMENSION(:), ALLOCATABLE :: ILIST ! link between urban types and indices
INTEGER :: II ! Loop counter
INTEGER :: JLOOP ! spatial loop counter
INTEGER :: JLIST ! loop counter on urban types
INTEGER :: KLIST ! loop counter on urban types
INTEGER :: IINDEX ! index of type for each point
INTEGER :: NCTL ! Control variable
INTEGER :: ILUOUT ! Unit number
!
REAL(KIND=JPRB) :: ZHOOK_HANDLE
!
!-------------------------------------------------------------------------------
!-------------------------------------------------------------------------------
!
IF (LHOOK) CALL DR_HOOK('INI_DATA_PARAM_TEB',0,ZHOOK_HANDLE)
!
!-------------------------------------------------------------------------------
!
!* 1. Builds the list of indices corresponding to the "type" field
! ------------------------------------------------------------------
!
ALLOCATE(ILIST(SIZE(KTYPE)))
ILIST(:) = -9999
!
! ##################################################################
! Elimination of unrealistic combinations of input data
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
! This is only valid for MApUCE data, and an alternative
! is required for other input datasets.
! ##################################################################
!
DO JLIST=1,SIZE(KTYPE)
!
! A) In the case the building type is "high-rise building" and the
! construction period is P1, the construction period is set
! to P2, since there are no high-rise buildings in P1.
!
IF ((DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_BGH).AND.(DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1)) THEN
!
DTT%NPAR_COL_BLD_AGE(JLIST)=BDD%NDESC_POS_AGE_P2
!
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
!
ENDIF
!
! B) In the case the building type is "local", the use is set to "LOCAL NON CHAUFFE"
!
IF (DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_LOCA) THEN
!
DTT%NPAR_USETYPE(JLIST)=BDD%NDESC_POS_USE_LNC
!
IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! C) In the case the building type coincides with individual housing, but the
! use with collective housing, the use is set to individual housing
! The building type is given priority
!
IF ( ((DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_PD) .OR.(DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_PSC).OR. &
(DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_PCIO).OR.(DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_PCIF)) .AND. &
(DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAC) ) THEN
!
DTT%NPAR_USETYPE(JLIST)=BDD%NDESC_POS_USE_HAI
!
IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! D) In the case the building type coincides with collective housing, but the
! use is INDIVIDUEL, the use is set to COLLECTIF
! The building type is given priority
!
IF ( ((DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_ID).OR.(DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_ICIO).OR. &
(DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_ICIF)).AND.(DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAI)) THEN
!
DTT%NPAR_USETYPE(JLIST)=BDD%NDESC_POS_USE_HAC
!
IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! E) In the case the building type is "BATIMENT D'ACTIVITE",
! but the use is INDIVIDUEL or COLLECTIF it is set to INDUSTRIEL
! The building type is given priority
!
IF ( ((DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAC).OR.(DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAI)) .AND. &
(DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_BA) ) THEN
!
DTT%NPAR_USETYPE(JLIST)=BDD%NDESC_POS_USE_IND
!
IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! F) In the case the use is LOCAL NON CHAUFFE, the building type is set to "LOCAL"
!
IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_LNC) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_LOCA
!
IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! G) For Office use, the building type must be ID/ICIO/ICIF/ for P1 and ID/ICIO/BGH for PX
!
IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_TER) THEN
!
IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
!
IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIO).AND. &
(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF)) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIO
!
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST), &
DTT%NPAR_USETYPE(JLIST),DTT%NPAR_P1TERRITORY(JLIST), &
DTT%NPAR_BLDCODE(JLIST))
!
ENDIF
!
ELSE
!
IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIO).AND. &
(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_BGH)) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIO
!
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST), &
DTT%NPAR_USETYPE(JLIST),DTT%NPAR_PXTERRITORY(JLIST), &
DTT%NPAR_BLDCODE(JLIST))
!
ENDIF
!
ENDIF
!
ENDIF
!
! H) In the case the use is SANTE and the building type is not ICIF or ICIO, the building type is set to ICIO.
!
IF ( (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_SAN).AND. &
((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIO)) ) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIO
!
IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! I) In the case the use is ENSEIGNEMENT and the building type
! is not ID/ICIO/ICIF the building type is set to ICIO.
!
IF ( (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_ENS).AND. &
((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIO).AND. &
(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF))) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIO
!
IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! K) In the case the use is CHATEAU the building type must be ID and the period must be P1
!
IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_CHA) THEN
!
DTT%NPAR_BLDTYPE(JLIST) = BDD%NDESC_POS_TYP_ID
DTT%NPAR_COL_BLD_AGE(JLIST) = BDD%NDESC_POS_AGE_P1
DTT%NPAR_IND_BLD_AGE(JLIST) = BDD%NDESC_POS_AGE_P1
!
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
!
ENDIF
!
! L) In the case the use is SPORTIF the building type must be BA
!
IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_SPO) THEN
!
DTT%NPAR_BLDTYPE(JLIST) = BDD%NDESC_POS_TYP_BA
!
IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! M) In the case the use is RELIGIEUX the building type must be ID/ICIF
!
IF ( (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_REL) .AND. &
((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF)) ) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIF
!
IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! N) In the case the use is AGRICOLE the building type must be BA
!
IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_AGR) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_BA
!
IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! O) In the case the use is SERRE the building type must be BA
!
IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_SER) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_BA
!
IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! P) In the case the use is INDUSTRIEL the building type must be BA
!
IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_IND) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_BA
!
IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! Q) In the case the use is COMMERCE the building type must be
! ID/ICIO/ICIF for P1
! ID/ICIF for P2 to P3
! ID/ICIF/BA for P4 to P7 and ID/ICIF for P1 to P3
!
IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_COM) THEN
!
IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
!
IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF).AND. &
(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIO)) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIF
!
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
!
ENDIF
!
ELSEIF (DTT%NPAR_COL_BLD_AGE(JLIST).LT.BDD%NDESC_POS_AGE_P4) THEN
!
IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF)) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIF
!
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
!
ENDIF
!
ELSE
!
IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF).AND. &
(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_BA)) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_BA
!
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
!
ENDIF
!
ENDIF
!
ENDIF
!
! R) In the case the use is COLLECTIF the building type must be ID/ICIO/ICIF/BGH
!
IF ( (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAC) .AND. &
((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID) .AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIO).AND. &
(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_BGH) ) ) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIO
!
IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
! S) In the case the use is INDIVIDUEL the building type must be PD/PSC/PCIO/PCIF
!
IF ( (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAI) .AND. &
((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PD) .AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PSC).AND. &
(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIO).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIF) )) THEN
!
DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_PD
!
IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
ENDIF
!
ENDDO
!
! ##################################################################
! Treatment of missing combinations of building type,
! use, construction period and territory
! ##################################################################
!
DO JLIST=1,SIZE(KTYPE)
!
! Test matching of initial building code
!
KTYPE(JLIST)=DTT%NPAR_BLDCODE(JLIST)
!
NCTL=0
DO KLIST=1,SIZE(BDD%NDESC_CODE_LIST)
IF (KTYPE(JLIST).EQ.BDD%NDESC_CODE_LIST(KLIST)) THEN
ILIST(JLIST) = KLIST
NCTL=NCTL+1
ENDIF
END DO
!
! There must only be one line in the .csv-table corresponding
! to the given building code
!
IF (NCTL.GT.1) CALL ABOR1_SFX("More than one line in csv-file corresponds to input")
!
! Treatment of missing data
!
IF (NCTL.EQ.0) THEN
!
! If the construction period is larger than 1, the territory is set to default
!
IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PD) .AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PSC).AND. &
(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIO).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIF)) THEN
!
IF (DTT%NPAR_COL_BLD_AGE(JLIST).NE.BDD%NDESC_POS_AGE_P1) THEN
!
DTT%NPAR_PXTERRITORY(JLIST)=BDD%NDESC_POS_PX_DEFAULT
!
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
!
KTYPE(JLIST)=DTT%NPAR_BLDCODE(JLIST)
!
ENDIF
!
ELSE
!
IF (DTT%NPAR_IND_BLD_AGE(JLIST).NE.BDD%NDESC_POS_AGE_P1) THEN
!
DTT%NPAR_PXTERRITORY(JLIST)=BDD%NDESC_POS_PX_DEFAULT
!
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
!
KTYPE(JLIST)=DTT%NPAR_BLDCODE(JLIST)
!
ENDIF
!
ENDIF
!
! Test matching of modified building code
!
NCTL=0
DO KLIST=1,SIZE(BDD%NDESC_CODE_LIST)
IF (KTYPE(JLIST).EQ.BDD%NDESC_CODE_LIST(KLIST)) THEN
ILIST(JLIST) = KLIST
NCTL=NCTL+1
ENDIF
ENDDO
IF (NCTL.GT.1) CALL ABOR1_SFX("More than one line in csv-file corresponds to input")
!
IF (NCTL.EQ.0) THEN
!
! In case of still missing arcitectural description,
! the constuction period is increased until a match is found.
! It is assmed, that the construction period numbering
! increases towards more recent periods
!
DO
!
IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PD) .AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PSC).AND. &
(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIO).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIF)) THEN
!
IF (DTT%NPAR_COL_BLD_AGE(JLIST).NE.BDD%NDESC_POS_AGE_P7) THEN
!
DTT%NPAR_COL_BLD_AGE(JLIST)=DTT%NPAR_COL_BLD_AGE(JLIST)+1
!
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
!
KTYPE(JLIST)=DTT%NPAR_BLDCODE(JLIST)
!
ELSE
CALL GET_LUOUT(HPROGRAM,ILUOUT)
WRITE(ILUOUT,*) " "
WRITE(ILUOUT,*) "In ini_data_param_teb "
WRITE(ILUOUT,*) "No building archetype found for the following combination "
WRITE(ILUOUT,*) "of building type, use, construction period and territory "
WRITE(ILUOUT,*) " "
WRITE(ILUOUT,*) "DTT%NPAR_BLDTYPE(JLIST) ",DTT%NPAR_BLDTYPE(JLIST)
WRITE(ILUOUT,*) "DTT%NPAR_COL_BLD_AGE(JLIST) ",DTT%NPAR_COL_BLD_AGE(JLIST)
WRITE(ILUOUT,*) "DTT%NPAR_USETYPE(JLIST) ",DTT%NPAR_USETYPE(JLIST)
WRITE(ILUOUT,*) "DTT%NPAR_PXTERRITORY(JLIST) ",DTT%NPAR_PXTERRITORY(JLIST)
CALL FLUSH(ILUOUT)
CALL ABOR1_SFX ("Missing building archetype, check report")
ENDIF
!
ELSE
!
IF (DTT%NPAR_IND_BLD_AGE(JLIST).NE.BDD%NDESC_POS_AGE_P7) THEN
!
DTT%NPAR_IND_BLD_AGE(JLIST)=DTT%NPAR_IND_BLD_AGE(JLIST)+1
!
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
!
KTYPE(JLIST)=DTT%NPAR_BLDCODE(JLIST)
!
ELSE
CALL GET_LUOUT(HPROGRAM,ILUOUT)
WRITE(ILUOUT,*) " "
WRITE(ILUOUT,*) "In ini_data_param_teb "
WRITE(ILUOUT,*) "No building archetype found for the following combination "
WRITE(ILUOUT,*) "of building type, use, construction period and territory "
WRITE(ILUOUT,*) " "
WRITE(ILUOUT,*) "DTT%NPAR_BLDTYPE(JLIST) ",DTT%NPAR_BLDTYPE(JLIST)
WRITE(ILUOUT,*) "DTT%NPAR_IND_BLD_AGE(JLIST) ",DTT%NPAR_IND_BLD_AGE(JLIST)
WRITE(ILUOUT,*) "DTT%NPAR_USETYPE(JLIST) ",DTT%NPAR_USETYPE(JLIST)
WRITE(ILUOUT,*) "DTT%NPAR_PXTERRITORY(JLIST) ",DTT%NPAR_PXTERRITORY(JLIST)
CALL FLUSH(ILUOUT)
CALL ABOR1_SFX ("Missing building archetype, check report")
ENDIF
!
ENDIF
!
! Test matching of modified building code
!
NCTL=0
DO KLIST=1,SIZE(BDD%NDESC_CODE_LIST)
IF (KTYPE(JLIST).EQ.BDD%NDESC_CODE_LIST(KLIST)) THEN
ILIST(JLIST) = KLIST
NCTL=NCTL+1
ENDIF
ENDDO
!
IF (NCTL.GT.0) THEN
EXIT
ENDIF
!
! Set territory to default
!
DTT%NPAR_PXTERRITORY(JLIST)=BDD%NDESC_POS_PX_DEFAULT
!
IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PD) .AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PSC).AND.&
(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIO).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIF)) THEN
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ELSE
CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
ENDIF
!
KTYPE(JLIST)=DTT%NPAR_BLDCODE(JLIST)
!
! Test matching of modified building code
!
NCTL=0
DO KLIST=1,SIZE(BDD%NDESC_CODE_LIST)
IF (KTYPE(JLIST).EQ.BDD%NDESC_CODE_LIST(KLIST)) THEN
ILIST(JLIST) = KLIST
NCTL=NCTL+1
ENDIF
ENDDO
!
IF (NCTL.GT.0) THEN
EXIT
ENDIF
!
ENDDO
!
ENDIF
!
ENDIF
!
ENDDO
!
! ###########################################################
! Initialisation of architectural characteristics
! ###########################################################
!
IINDEX = 0
!
!-------------------------------------------------------------------------------
DO JLOOP=1,SIZE(KTYPE)
!-------------------------------------------------------------------------------
!
IINDEX=ILIST(JLOOP)
!
!* 1. town parameters depending on urban characteristics
! --------------------------------------------------------
!
! Road
!
PALB_ROAD(JLOOP)=BDD%XDESC_ALB_ROAD(IINDEX)
ENDIF
IF (PRESENT(PEMIS_ROAD)) THEN
PEMIS_ROAD(JLOOP)=BDD%XDESC_EMIS_ROAD(IINDEX)
ENDIF
IF (PRESENT(PHC_ROAD)) THEN
PHC_ROAD(JLOOP,:)= BDD%XDESC_HC_ROAD(IINDEX,:)
ENDIF
IF (PRESENT(PTC_ROAD)) THEN
PTC_ROAD(JLOOP,:)= BDD%XDESC_TC_ROAD(IINDEX,:)
ENDIF
IF (PRESENT(PD_ROAD)) THEN
PD_ROAD(JLOOP,:)= BDD%XDESC_D_ROAD(IINDEX,:)
! Roof
PALB_ROOF(JLOOP)=BDD%XDESC_ALB_ROOF(IINDEX)
ENDIF
IF (PRESENT(PEMIS_ROOF)) THEN
PEMIS_ROOF(JLOOP)=BDD%XDESC_EMIS_ROOF(IINDEX)
ENDIF
IF (PRESENT(PHC_ROOF)) THEN
PHC_ROOF(JLOOP,:)= BDD%XDESC_HC_ROOF(IINDEX,:)
ENDIF
IF (PRESENT(PTC_ROOF)) THEN
PTC_ROOF(JLOOP,:)= BDD%XDESC_TC_ROOF(IINDEX,:)
ENDIF
IF (PRESENT(PD_ROOF)) THEN
PD_ROOF(JLOOP,:)= BDD%XDESC_D_ROOF(IINDEX,:)
!
! Wall
!
IF (PRESENT(PALB_WALL)) THEN
PALB_WALL(JLOOP)=BDD%XDESC_ALB_WALL(IINDEX)
ENDIF
IF (PRESENT(PEMIS_WALL)) THEN
PEMIS_WALL(JLOOP)=BDD%XDESC_EMIS_WALL(IINDEX)
ENDIF
IF (PRESENT(PHC_WALL)) THEN
PHC_WALL(JLOOP,:)= BDD%XDESC_HC_WALL(IINDEX,:)
ENDIF
IF (PRESENT(PTC_WALL)) THEN
PTC_WALL(JLOOP,:)= BDD%XDESC_TC_WALL(IINDEX,:)
ENDIF
PD_WALL(JLOOP,:)= BDD%XDESC_D_WALL(IINDEX,:)
!
! Position of isolation layers
!
IF (PRESENT(NISOROOFPOS)) THEN
NISOROOFPOS(JLOOP) = BDD%NDESC_ISOROOFPOS(IINDEX)
ENDIF
IF (PRESENT(NISOWALLPOS)) THEN
NISOWALLPOS(JLOOP) = BDD%NDESC_ISOWALLPOS(IINDEX)
ENDIF
!
! Floor
!
PHC_FLOOR(JLOOP,:)= BDD%XDESC_HC_FLOOR(IINDEX,:)
ENDIF
IF (PRESENT(PTC_FLOOR)) THEN
PTC_FLOOR(JLOOP,:)= BDD%XDESC_TC_FLOOR(IINDEX,:)
ENDIF
IF (PRESENT(PD_FLOOR)) THEN
PD_FLOOR(JLOOP,:)= BDD%XDESC_D_FLOOR(IINDEX,:)
! Mass
IF (PRESENT(PHC_MASS)) THEN
PHC_MASS(JLOOP,:)= BDD%XDESC_HC_MASS(IINDEX,:)
ENDIF
IF (PRESENT(PTC_MASS)) THEN
PTC_MASS(JLOOP,:)= BDD%XDESC_TC_MASS(IINDEX,:)
ENDIF
IF (PRESENT(PD_MASS)) THEN
PD_MASS(JLOOP,:)= BDD%XDESC_D_MASS(IINDEX,:)
ENDIF
IF (PRESENT(PISMASS)) THEN
PISMASS(JLOOP) = BDD%XDESC_ISMASS(IINDEX)
IF (PRESENT(PN50)) THEN
PN50(JLOOP) = BDD%XDESC_N50(IINDEX)
ENDIF
!
IF (PRESENT(PGR)) THEN
!
IF (PRESENT(PU_WIN)) THEN
PU_WIN(JLOOP) = BDD%XDESC_U_WIN(IINDEX)
IF (PRESENT(PSHGC)) THEN
PSHGC(JLOOP) = BDD%XDESC_SHGC(IINDEX)
IF (PRESENT(PSHGC_SH)) THEN
PSHGC_SH(JLOOP) = BDD%XDESC_SHGC_SH(IINDEX)
ENDIF
!
IF (PRESENT(PSHADEARCHI)) THEN
PSHADEARCHI(JLOOP) = BDD%XDESC_SHADEARCHI(IINDEX)
IF (PRESENT(PISMECH)) THEN
PISMECH(JLOOP) = BDD%XDESC_ISMECH(IINDEX)
IF (PRESENT(PMECHRATE)) THEN
PMECHRATE(JLOOP) = BDD%XDESC_MECHRATE(IINDEX)
ENDIF
!
IF (PRESENT(PGREENROOF)) THEN
PGREENROOF(JLOOP) = BDD%XDESC_GREENROOF(IINDEX)
ENDIF
!
IF (PRESENT(PEMIS_PANEL)) THEN
PEMIS_PANEL(JLOOP) = BDD%XDESC_EMIS_PANEL(IINDEX)
ENDIF
!
IF (PRESENT(PALB_PANEL)) THEN
PALB_PANEL(JLOOP) = BDD%XDESC_ALB_PANEL(IINDEX)
ENDIF
!
IF (PRESENT(PEFF_PANEL)) THEN
PEFF_PANEL(JLOOP) = BDD%XDESC_EFF_PANEL(IINDEX)
ENDIF
!
IF (PRESENT(PFRAC_PANEL)) THEN
PFRAC_PANEL(JLOOP) = BDD%XDESC_FRAC_PANEL(IINDEX)
! ----------------------------------------------------
! Architectural parameters not read from table
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
! ---------------------------------------------------
!
IF (PRESENT(PCAP_SYS_HEAT)) THEN
PCAP_SYS_HEAT(JLOOP) = 100.
ENDIF
!
IF (PRESENT(PCAP_SYS_RAT)) THEN
PCAP_SYS_RAT(JLOOP) = 90.
ENDIF
!
IF (PRESENT(PT_ADP)) THEN
PT_ADP(JLOOP) = 285.66
ENDIF
!
IF (PRESENT(PM_SYS_RAT)) THEN
PM_SYS_RAT(JLOOP) = 0.0067
ENDIF
!
IF (PRESENT(PT_SIZE_MAX)) THEN
PT_SIZE_MAX(JLOOP) = 301.95
ENDIF
!
IF (PRESENT(PT_SIZE_MIN)) THEN
PT_SIZE_MIN(JLOOP) = 268.96
ENDIF
!
IF (PRESENT(PFLOOR_HEIGHT)) THEN
PFLOOR_HEIGHT(JLOOP) = 2.9
ENDIF
!
IF (PRESENT(PROUGH_ROOF)) THEN
PROUGH_ROOF(JLOOP) = 1.52
ENDIF
!
IF (PRESENT(PROUGH_WALL)) THEN
PROUGH_WALL(JLOOP) = 1.52
ENDIF
!
END DO
!
DEALLOCATE(ILIST)
!
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
1185
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
1199
1200
1201
1202
1203
1204
1205
1206
1207
1208
1209
1210
1211
1212
1213
1214
1215
1216
1217
1218
1219
1220
1221
1222
1223
1224
1225
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1249
1250
1251
1252
1253
1254
1255
1256
1257
1258
1259
1260
1261
1262
1263
1264
1265
1266
1267
1268
1269
1270
1271
1272
1273
1274
1275
1276
1277
1278
1279
1280
1281
1282
1283
1284
1285
1286
1287
1288
1289
1290
1291
1292
1293
1294
1295
1296
1297
1298
1299
1300
1301
1302
1303
1304
1305
1306
1307
1308
1309
1310
1311
1312
1313
1314
1315
1316
1317
1318
1319
1320
1321
1322
1323
1324
1325
1326
1327
1328
1329
1330
1331
1332
1333
1334
1335
1336
1337
1338
1339
1340
1341
1342
1343
1344
1345
1346
1347
1348
1349
1350
1351
1352
1353
1354
1355
1356
1357
1358
1359
1360
1361
1362
1363
1364
1365
1366
1367
1368
1369
1370
1371
1372
1373
1374
1375
1376
1377
1378
1379
1380
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
1392
1393
1394
1395
1396
1397
1398
1399
1400
1401
1402
1403
1404
1405
1406
1407
1408
1409
1410
1411
1412
1413
1414
1415
1416
1417
1418
1419
1420
1421
1422
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
1438
1439
1440
1441
1442
1443
1444
1445
1446
1447
1448
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1461
1462
1463
1464
1465
1466
1467
1468
1469
1470
1471
1472
1473
1474
1475
1476
1477
1478
1479
1480
1481
1482
1483
1484
1485
1486
1487
1488
1489
1490
1491
1492
1493
1494
1495
1496
1497
1498
1499
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1539
1540
1541
1542
1543
1544
1545
1546
1547
1548
1549
1550
1551
1552
1553
1554
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1598
1599
1600
1601
1602
1603
1604
1605
1606
1607
1608
1609
1610
1611
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1624
1625
1626
1627
1628
1629
1630
1631
1632
1633
1634
1635
1636
1637
1638
1639
1640
1641
1642
1643
1644
1645
1646
1647
1648
1649
1650
1651
1652
1653
1654
1655
1656
1657
! ###########################################################
! Initialisation of behavioural characteristics
! When using the building description files, it is possible
! to simulate with 1 or 6 compartments
! For 6-compartments-case, the compartments are defined as follows
! - (1): FORT CRE (low design temperature, if applicable)
! - (2): FAIBLE CRE (high design temperature, if applicable)
! - (3): Mean between FORT CRE and FAIBLE CRE (if applicable)
! - (4): non-heated fraction of the building
! - (5): COMMERCIAL fraction (if applicable)
! - (6): TERTIARE fraction (if applicable)
!
! For the 1-compartment-case, the input values are averaged
! to represent the variety of behaviours as good as possible
!
! More details can be found in Schoetter et al. (2017), GMD.
!
! ###########################################################
!
! Initialisation of the fraction of compartments
!
DO JLIST=1,SIZE(DTT%NPAR_USETYPE)
!
IF (PRESENT(PFRACOMP)) THEN
!
IF (SIZE(PFRACOMP,2).EQ.1) THEN
!
PFRACOMP(JLIST,1) = 1.0
!
ELSEIF (SIZE(PFRACOMP,2).EQ.6) THEN
!
IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAC) THEN
!
! For main use = COLLECTIVE housing, a non-heated fraction,
! a COMMERCIAL and TERTIARY fraction and 3 residential
! compartments with 3 different heating design temperatures are considered.
! The non-heated fraction related to this specific building archetype
! It will be used to normalise the commercial and office fraction
!
PFRACOMP(JLIST,4) = BDD%XDESC_FNOHEAT_AVG(DTT%NPAR_USETYPE(JLIST)) + &
BDD%XDESC_FNOHEAT_MOD(DTT%NPAR_USETYPE(JLIST))*(2*DTT%XPAR_CRE_APPT(JLIST)-1)
!
PFRACOMP(JLIST,5) = DTT%XPAR_FRACCOM(JLIST)*(1.0-PFRACOMP(JLIST,4))
PFRACOMP(JLIST,6) = DTT%XPAR_FRACTER(JLIST)*(1.0-PFRACOMP(JLIST,4))
!
PFRACOMP(JLIST,4) = ( 1.0 - DTT%XPAR_FRACNHE(JLIST) - DTT%XPAR_FRACIND(JLIST) ) * ( &
BDD%XDESC_FNOHEAT_AVG(DTT%NPAR_USETYPE(JLIST)) + &
BDD%XDESC_FNOHEAT_MOD(DTT%NPAR_USETYPE(JLIST)) * (2*DTT%XPAR_CRE_APPT(JLIST)-1) ) + &
DTT%XPAR_FRACNHE(JLIST) + DTT%XPAR_FRACIND(JLIST)
!
PFRACOMP(JLIST,1) = (1.0 - PFRACOMP(JLIST,4) - PFRACOMP(JLIST,5) - PFRACOMP(JLIST,6)) * &
(DTT%XPAR_CRE_APPT(JLIST) * BDD%XDESC_FLDT(BDD%NDESC_POS_HAC_FORTCRE) + &
(1.0-DTT%XPAR_CRE_APPT(JLIST)) * BDD%XDESC_FLDT(BDD%NDESC_POS_HAC_FAIBCRE))
!
PFRACOMP(JLIST,2) = (1.0 - PFRACOMP(JLIST,4) - PFRACOMP(JLIST,5) - PFRACOMP(JLIST,6)) * &
(DTT%XPAR_CRE_APPT(JLIST) * BDD%XDESC_FHDT(BDD%NDESC_POS_HAC_FORTCRE) + &
(1.0-DTT%XPAR_CRE_APPT(JLIST)) * BDD%XDESC_FHDT(BDD%NDESC_POS_HAC_FAIBCRE))
!
PFRACOMP(JLIST,3) = (1.0 - PFRACOMP(JLIST,4) - PFRACOMP(JLIST,5) - PFRACOMP(JLIST,6)) * &
(DTT%XPAR_CRE_APPT(JLIST) * BDD%XDESC_FIDT(BDD%NDESC_POS_HAC_FORTCRE) + &
(1.0-DTT%XPAR_CRE_APPT(JLIST)) * BDD%XDESC_FIDT(BDD%NDESC_POS_HAC_FAIBCRE))
!
ELSEIF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAI) THEN
!
! For main use = INDIVIDUAL housing, a non-heated fraction,
! a COMMERCIAL and TERTIARY fraction and 3 residential
! compartments with 3 different heating design temperatures are considered.
! The non-heated fraction related to this specific building archetype
! It will be used to normalise the commercial and office fraction
!
PFRACOMP(JLIST,4) = BDD%XDESC_FNOHEAT_AVG(DTT%NPAR_USETYPE(JLIST)) + &
BDD%XDESC_FNOHEAT_MOD(DTT%NPAR_USETYPE(JLIST)) * (2*DTT%XPAR_CRE_MAIS(JLIST)-1)
!
PFRACOMP(JLIST,5) = DTT%XPAR_FRACCOM(JLIST)*(1.0-PFRACOMP(JLIST,4))
PFRACOMP(JLIST,6) = DTT%XPAR_FRACTER(JLIST)*(1.0-PFRACOMP(JLIST,4))
!
PFRACOMP(JLIST,4) = ( 1.0 - DTT%XPAR_FRACNHE(JLIST) - DTT%XPAR_FRACIND(JLIST) ) * ( &
BDD%XDESC_FNOHEAT_AVG(DTT%NPAR_USETYPE(JLIST)) + &
BDD%XDESC_FNOHEAT_MOD(DTT%NPAR_USETYPE(JLIST)) * (2*DTT%XPAR_CRE_MAIS(JLIST)-1) ) + &
DTT%XPAR_FRACNHE(JLIST) + DTT%XPAR_FRACIND(JLIST)
!
PFRACOMP(JLIST,1) = (1.0 - PFRACOMP(JLIST,4) - PFRACOMP(JLIST,5) - PFRACOMP(JLIST,6)) * &
(DTT%XPAR_CRE_MAIS(JLIST) * BDD%XDESC_FLDT(BDD%NDESC_POS_HAI_FORTCRE) + &
(1.0-DTT%XPAR_CRE_MAIS(JLIST)) * BDD%XDESC_FLDT(BDD%NDESC_POS_HAI_FAIBCRE))
!
PFRACOMP(JLIST,2) = (1.0 - PFRACOMP(JLIST,4) - PFRACOMP(JLIST,5) - PFRACOMP(JLIST,6)) * &
(DTT%XPAR_CRE_MAIS(JLIST) * BDD%XDESC_FHDT(BDD%NDESC_POS_HAI_FORTCRE) + &
(1.0-DTT%XPAR_CRE_MAIS(JLIST)) * BDD%XDESC_FHDT(BDD%NDESC_POS_HAI_FAIBCRE))
!
PFRACOMP(JLIST,3) = (1.0 - PFRACOMP(JLIST,4) - PFRACOMP(JLIST,5) - PFRACOMP(JLIST,6)) * &
(DTT%XPAR_CRE_MAIS(JLIST) * BDD%XDESC_FIDT(BDD%NDESC_POS_HAI_FORTCRE) + &
(1.0-DTT%XPAR_CRE_MAIS(JLIST)) * BDD%XDESC_FIDT(BDD%NDESC_POS_HAI_FAIBCRE))
!
ELSEIF ( (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_COM).OR.(DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_SAN) .OR. &
(DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_ENS).OR.(DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_TER) ) THEN
!
! For the main use = TERTIARY, COMMERCIAL, HEALTH and EDUCATION
! a non-heated fraction and 3 compartments with different design temperatures
! of heating and climatisation are considered
!
PFRACOMP(JLIST,4) = (1.0 - DTT%XPAR_FRACNHE(JLIST) - DTT%XPAR_FRACIND(JLIST) ) * &
BDD%XDESC_FNOHEAT_AVG(DTT%NPAR_USETYPE(JLIST)) + &
DTT%XPAR_FRACNHE(JLIST) + DTT%XPAR_FRACIND(JLIST)
!
PFRACOMP(JLIST,5) = 0.0
PFRACOMP(JLIST,6) = 0.0
PFRACOMP(JLIST,1) = (1.0 - PFRACOMP(JLIST,4) - PFRACOMP(JLIST,5) - PFRACOMP(JLIST,6)) * 0.33
PFRACOMP(JLIST,2) = (1.0 - PFRACOMP(JLIST,4) - PFRACOMP(JLIST,5) - PFRACOMP(JLIST,6)) * 0.34
PFRACOMP(JLIST,3) = (1.0 - PFRACOMP(JLIST,4) - PFRACOMP(JLIST,5) - PFRACOMP(JLIST,6)) * 0.33
!
ELSE
!
! Only a non-heated fraction is considered
!
PFRACOMP(JLIST,4) = (1.0-DTT%XPAR_FRACNHE(JLIST) - DTT%XPAR_FRACIND(JLIST))* &
BDD%XDESC_FNOHEAT_AVG(DTT%NPAR_USETYPE(JLIST)) + &
DTT%XPAR_FRACNHE(JLIST) + DTT%XPAR_FRACIND(JLIST)
PFRACOMP(JLIST,5) = 0.0
PFRACOMP(JLIST,6) = 0.0
PFRACOMP(JLIST,1) = 1.0 - PFRACOMP(JLIST,4) - PFRACOMP(JLIST,5) - PFRACOMP(JLIST,6)
PFRACOMP(JLIST,2) = 0.0
PFRACOMP(JLIST,3) = 0.0
!
ENDIF
!
ELSE
CALL ABOR1_SFX("No rule implemented for this number of compartments")
ENDIF
!
! Check whether the individual compartment fractions by more than 1.0E-6 wrong
!
DO II=1,SIZE(PFRACOMP,2)
IF ((PFRACOMP(JLIST,II).LT.-1.0E-6).OR.(PFRACOMP(JLIST,II).GT.(1.0+1.0E-6))) THEN
CALL ABOR1_SFX("INI_DATA_PARAM_TEB: Wrong fraction of compartments")
ENDIF
ENDDO
!
! Very small deviations from 0.0 or 1.0 are corrected
!
WHERE (PFRACOMP(JLIST,:).LT.0.0)
PFRACOMP(JLIST,:) = 0.0
ELSEWHERE (PFRACOMP(JLIST,:).GT.1.0)
PFRACOMP(JLIST,:) = 1.0
ENDWHERE
!
! Check whether the sum is far from 1.0
!
IF (ABS(SUM(PFRACOMP(JLIST,:))-1.0).GT.1.0E-6) THEN
CALL ABOR1_SFX("INI_DATA_PARAM_TEB : Wrong initial sum of compartment fractions")
ENDIF
!
! Renormalise the sum
!
PFRACOMP(JLIST,:) = PFRACOMP(JLIST,:)/SUM(PFRACOMP(JLIST,:))
!
! Check whether the renormalised sum is exactly 1.0
!
IF (ABS(SUM(PFRACOMP(JLIST,:))-1.0).GT.XSURF_EPSILON) THEN
CALL ABOR1_SFX("INI_DATA_PARAM_TEB : Wrong final sum of compartment fractions")
ENDIF
!
ENDIF
!
ENDDO
!
! ###########################################################
!
! Initialisation of heating-related variables
!
DO JLIST=1,SIZE(DTT%NPAR_USETYPE)
!
IF (PRESENT(PTHEAT_OCCD)) THEN
!
IF (SIZE(PTHEAT_OCCD,2).EQ.1) THEN
PTHEAT_OCCD(JLIST,1) = BDD%XDESC_THEAT_OCCD_AVG(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PTHEAT_OCCD,2).EQ.6) THEN
PTHEAT_OCCD(JLIST,1) = BDD%XDESC_THEAT_OCCD_AVG(DTT%NPAR_USETYPE(JLIST))- &
BDD%XDESC_THEAT_OCCD_MOD(DTT%NPAR_USETYPE(JLIST))
PTHEAT_OCCD(JLIST,2) = BDD%XDESC_THEAT_OCCD_AVG(DTT%NPAR_USETYPE(JLIST))+ &
BDD%XDESC_THEAT_OCCD_MOD(DTT%NPAR_USETYPE(JLIST))
PTHEAT_OCCD(JLIST,3) = BDD%XDESC_THEAT_OCCD_AVG(DTT%NPAR_USETYPE(JLIST))
PTHEAT_OCCD(JLIST,4) = 200.0
PTHEAT_OCCD(JLIST,5) = BDD%XDESC_THEAT_OCCD_AVG(BDD%NDESC_POS_USE_COM)
PTHEAT_OCCD(JLIST,6) = BDD%XDESC_THEAT_OCCD_AVG(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX("No rule for this number of compartments")
ENDIF
!
ENDIF
!
IF (PRESENT(PTHEAT_OCCN)) THEN
!
IF (SIZE(PTHEAT_OCCN,2).EQ.1) THEN
PTHEAT_OCCN(JLIST,1) = BDD%XDESC_THEAT_OCCN_AVG(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PTHEAT_OCCN,2).EQ.6) THEN
PTHEAT_OCCN(JLIST,1) = BDD%XDESC_THEAT_OCCN_AVG(DTT%NPAR_USETYPE(JLIST))- &
BDD%XDESC_THEAT_OCCN_MOD(DTT%NPAR_USETYPE(JLIST))
PTHEAT_OCCN(JLIST,2) = BDD%XDESC_THEAT_OCCN_AVG(DTT%NPAR_USETYPE(JLIST))+ &
BDD%XDESC_THEAT_OCCN_MOD(DTT%NPAR_USETYPE(JLIST))
PTHEAT_OCCN(JLIST,3) = BDD%XDESC_THEAT_OCCN_AVG(DTT%NPAR_USETYPE(JLIST))
PTHEAT_OCCN(JLIST,4) = 200.0
PTHEAT_OCCN(JLIST,5) = BDD%XDESC_THEAT_OCCN_AVG(BDD%NDESC_POS_USE_COM)
PTHEAT_OCCN(JLIST,6) = BDD%XDESC_THEAT_OCCN_AVG(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX("No rule for this number of compartments")
ENDIF
!
ENDIF
!
IF (PRESENT(PTHEAT_VCDD)) THEN
!
IF (SIZE(PTHEAT_VCDD,2).EQ.1) THEN
PTHEAT_VCDD(JLIST,1) = BDD%XDESC_THEAT_VCDD_AVG(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PTHEAT_VCDD,2).EQ.6) THEN
PTHEAT_VCDD(JLIST,1) = BDD%XDESC_THEAT_VCDD_AVG(DTT%NPAR_USETYPE(JLIST))- &
BDD%XDESC_THEAT_VCDD_MOD(DTT%NPAR_USETYPE(JLIST))
PTHEAT_VCDD(JLIST,2) = BDD%XDESC_THEAT_VCDD_AVG(DTT%NPAR_USETYPE(JLIST))+ &
BDD%XDESC_THEAT_VCDD_MOD(DTT%NPAR_USETYPE(JLIST))
PTHEAT_VCDD(JLIST,3) = BDD%XDESC_THEAT_VCDD_AVG(DTT%NPAR_USETYPE(JLIST))
PTHEAT_VCDD(JLIST,4) = 200.0
PTHEAT_VCDD(JLIST,5) = BDD%XDESC_THEAT_VCDD_AVG(BDD%NDESC_POS_USE_COM)
PTHEAT_VCDD(JLIST,6) = BDD%XDESC_THEAT_VCDD_AVG(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX("No rule for this number of compartments")
ENDIF
!
ENDIF
!
IF (PRESENT(PTHEAT_VCDN)) THEN
!
IF (SIZE(PTHEAT_VCDN,2).EQ.1) THEN
PTHEAT_VCDN(JLIST,1) = BDD%XDESC_THEAT_VCDN_AVG(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PTHEAT_VCDN,2).EQ.6) THEN
PTHEAT_VCDN(JLIST,1) = BDD%XDESC_THEAT_VCDN_AVG(DTT%NPAR_USETYPE(JLIST))- &
BDD%XDESC_THEAT_VCDN_MOD(DTT%NPAR_USETYPE(JLIST))
PTHEAT_VCDN(JLIST,2) = BDD%XDESC_THEAT_VCDN_AVG(DTT%NPAR_USETYPE(JLIST))+ &
BDD%XDESC_THEAT_VCDN_MOD(DTT%NPAR_USETYPE(JLIST))
PTHEAT_VCDN(JLIST,3) = BDD%XDESC_THEAT_VCDN_AVG(DTT%NPAR_USETYPE(JLIST))
PTHEAT_VCDN(JLIST,4) = 200.0
PTHEAT_VCDN(JLIST,5) = BDD%XDESC_THEAT_VCDN_AVG(BDD%NDESC_POS_USE_COM)
PTHEAT_VCDN(JLIST,6) = BDD%XDESC_THEAT_VCDN_AVG(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX("No rule for this number of compartments")
ENDIF
!
ENDIF
!
IF (PRESENT(PTHEAT_VCLD)) THEN
!
IF (SIZE(PTHEAT_VCLD,2).EQ.1) THEN
PTHEAT_VCLD(JLIST,1) = BDD%XDESC_THEAT_VCLD_AVG(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PTHEAT_VCLD,2).EQ.6) THEN
PTHEAT_VCLD(JLIST,1) = BDD%XDESC_THEAT_VCLD_AVG(DTT%NPAR_USETYPE(JLIST))- &
BDD%XDESC_THEAT_VCLD_MOD(DTT%NPAR_USETYPE(JLIST))
PTHEAT_VCLD(JLIST,2) = BDD%XDESC_THEAT_VCLD_AVG(DTT%NPAR_USETYPE(JLIST))+ &
BDD%XDESC_THEAT_VCLD_MOD(DTT%NPAR_USETYPE(JLIST))
PTHEAT_VCLD(JLIST,3) = BDD%XDESC_THEAT_VCLD_AVG(DTT%NPAR_USETYPE(JLIST))
PTHEAT_VCLD(JLIST,4) = 200.0
PTHEAT_VCLD(JLIST,5) = BDD%XDESC_THEAT_VCLD_AVG(BDD%NDESC_POS_USE_COM)
PTHEAT_VCLD(JLIST,6) = BDD%XDESC_THEAT_VCLD_AVG(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX("No rule for this number of compartments")
ENDIF
!
ENDIF
!
ENDDO
!
! Initialisation of cooling-related variables
!
DO JLIST=1,SIZE(DTT%NPAR_USETYPE)
!
IF (PRESENT(PTCOOL_OCCD)) THEN
IF (SIZE(PTCOOL_OCCD,2).EQ.1) THEN
PTCOOL_OCCD(JLIST,1) = BDD%XDESC_TCOOL_OCCD(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PTCOOL_OCCD,2).EQ.6) THEN
PTCOOL_OCCD(JLIST,1) = BDD%XDESC_TCOOL_OCCD(DTT%NPAR_USETYPE(JLIST))
PTCOOL_OCCD(JLIST,2) = BDD%XDESC_TCOOL_OCCD(DTT%NPAR_USETYPE(JLIST))
PTCOOL_OCCD(JLIST,3) = BDD%XDESC_TCOOL_OCCD(DTT%NPAR_USETYPE(JLIST))
PTCOOL_OCCD(JLIST,4) = 400.0
PTCOOL_OCCD(JLIST,5) = BDD%XDESC_TCOOL_OCCD(BDD%NDESC_POS_USE_COM)
PTCOOL_OCCD(JLIST,6) = BDD%XDESC_TCOOL_OCCD(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PTCOOL_OCCN)) THEN
IF (SIZE(PTCOOL_OCCN,2).EQ.1) THEN
PTCOOL_OCCN(JLIST,1) = BDD%XDESC_TCOOL_OCCN(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PTCOOL_OCCN,2).EQ.6) THEN
PTCOOL_OCCN(JLIST,1) = BDD%XDESC_TCOOL_OCCN(DTT%NPAR_USETYPE(JLIST))
PTCOOL_OCCN(JLIST,2) = BDD%XDESC_TCOOL_OCCN(DTT%NPAR_USETYPE(JLIST))
PTCOOL_OCCN(JLIST,3) = BDD%XDESC_TCOOL_OCCN(DTT%NPAR_USETYPE(JLIST))
PTCOOL_OCCN(JLIST,4) = 400.0
PTCOOL_OCCN(JLIST,5) = BDD%XDESC_TCOOL_OCCN(BDD%NDESC_POS_USE_COM)
PTCOOL_OCCN(JLIST,6) = BDD%XDESC_TCOOL_OCCN(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PTCOOL_VCDD)) THEN
IF (SIZE(PTCOOL_VCDD,2).EQ.1) THEN
PTCOOL_VCDD(JLIST,1) = BDD%XDESC_TCOOL_VCDD(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PTCOOL_VCDD,2).EQ.6) THEN
PTCOOL_VCDD(JLIST,1) = BDD%XDESC_TCOOL_VCDD(DTT%NPAR_USETYPE(JLIST))
PTCOOL_VCDD(JLIST,2) = BDD%XDESC_TCOOL_VCDD(DTT%NPAR_USETYPE(JLIST))
PTCOOL_VCDD(JLIST,3) = BDD%XDESC_TCOOL_VCDD(DTT%NPAR_USETYPE(JLIST))
PTCOOL_VCDD(JLIST,4) = 400.0
PTCOOL_VCDD(JLIST,5) = BDD%XDESC_TCOOL_VCDD(BDD%NDESC_POS_USE_COM)
PTCOOL_VCDD(JLIST,6) = BDD%XDESC_TCOOL_VCDD(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PTCOOL_VCDN)) THEN
IF (SIZE(PTCOOL_VCDN,2).EQ.1) THEN
PTCOOL_VCDN(JLIST,1) = BDD%XDESC_TCOOL_VCDN(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PTCOOL_VCDN,2).EQ.6) THEN
PTCOOL_VCDN(JLIST,1) = BDD%XDESC_TCOOL_VCDN(DTT%NPAR_USETYPE(JLIST))
PTCOOL_VCDN(JLIST,2) = BDD%XDESC_TCOOL_VCDN(DTT%NPAR_USETYPE(JLIST))
PTCOOL_VCDN(JLIST,3) = BDD%XDESC_TCOOL_VCDN(DTT%NPAR_USETYPE(JLIST))
PTCOOL_VCDN(JLIST,4) = 400.0
PTCOOL_VCDN(JLIST,5) = BDD%XDESC_TCOOL_VCDN(BDD%NDESC_POS_USE_COM)
PTCOOL_VCDN(JLIST,6) = BDD%XDESC_TCOOL_VCDN(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PTCOOL_VCLD)) THEN
IF (SIZE(PTCOOL_VCLD,2).EQ.1) THEN
PTCOOL_VCLD(JLIST,1) = BDD%XDESC_TCOOL_VCLD(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PTCOOL_VCLD,2).EQ.6) THEN
PTCOOL_VCLD(JLIST,1) = BDD%XDESC_TCOOL_VCLD(DTT%NPAR_USETYPE(JLIST))
PTCOOL_VCLD(JLIST,2) = BDD%XDESC_TCOOL_VCLD(DTT%NPAR_USETYPE(JLIST))
PTCOOL_VCLD(JLIST,3) = BDD%XDESC_TCOOL_VCLD(DTT%NPAR_USETYPE(JLIST))
PTCOOL_VCLD(JLIST,4) = 400.0
PTCOOL_VCLD(JLIST,5) = BDD%XDESC_TCOOL_VCLD(BDD%NDESC_POS_USE_COM)
PTCOOL_VCLD(JLIST,6) = BDD%XDESC_TCOOL_VCLD(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PF_WATER_COND)) THEN
PF_WATER_COND(JLIST)=BDD%XDESC_F_WATER_COND(DTT%NPAR_USETYPE(JLIST))
ENDIF
!
IF (PRESENT(PF_WASTE_CAN)) THEN
PF_WASTE_CAN(JLIST) = BDD%XDESC_F_WASTE_CAN(DTT%NPAR_USETYPE(JLIST))
ENDIF
!
IF (PRESENT(PCOP_RAT)) THEN
PCOP_RAT(JLIST)=BDD%XDESC_COP_RAT(DTT%NPAR_USETYPE(JLIST))
ENDIF
!
IF (PRESENT(PHR_TARGET)) THEN
PHR_TARGET(JLIST)=BDD%XDESC_HR_TARGET(DTT%NPAR_USETYPE(JLIST))
ENDIF
!
ENDDO
!
! Initialisation of internal heat release-related variables
! At the moment the same internal heat release is distributed
! over all the heating design temperature differenciated compartments
!
DO JLIST=1,SIZE(DTT%NPAR_USETYPE)
!
IF (PRESENT(PQIN)) THEN
!
IF (SIZE(PQIN,2).EQ.1) THEN
PQIN(JLIST,1) = BDD%XDESC_QIN(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PQIN,2).EQ.6) THEN
!
IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAI) THEN
PQIN(JLIST,1) = BDD%XDESC_QIN(DTT%NPAR_USETYPE(JLIST)) + &
MAX(0.0,(2*DTT%XPAR_FOEQI_MAIS(JLIST)-1)*BDD%XDESC_QIN_ADDBEHAV(DTT%NPAR_USETYPE(JLIST))) - &
MAX(0.0,(2*DTT%XPAR_FAEQI_MAIS(JLIST)-1)*BDD%XDESC_QIN_ADDBEHAV(DTT%NPAR_USETYPE(JLIST)))
ELSE
PQIN(JLIST,1) = BDD%XDESC_QIN(DTT%NPAR_USETYPE(JLIST)) + &
MAX(0.0,(2*DTT%XPAR_FOEQI_APPT(JLIST)-1)*BDD%XDESC_QIN_ADDBEHAV(DTT%NPAR_USETYPE(JLIST))) - &
MAX(0.0,(2*DTT%XPAR_FAEQI_APPT(JLIST)-1)*BDD%XDESC_QIN_ADDBEHAV(DTT%NPAR_USETYPE(JLIST)))
ENDIF
!
PQIN(JLIST,2) = PQIN(JLIST,1)
PQIN(JLIST,3) = PQIN(JLIST,1)
PQIN(JLIST,4) = PQIN(JLIST,1)
PQIN(JLIST,5) = BDD%XDESC_QIN(BDD%NDESC_POS_USE_COM)
PQIN(JLIST,6) = BDD%XDESC_QIN(BDD%NDESC_POS_USE_TER)
!
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
!
DO II=1,SIZE(PQIN,2)
IF (PQIN(JLIST,II).LT.-XSURF_EPSILON) THEN
CALL ABOR1_SFX("INI_DATA_PARAM_TEB:Negative value for nominative internal heat release")
ENDIF
ENDDO
!
ENDIF
!
IF (PRESENT(PQIN_FRAD)) THEN
PQIN_FRAD(JLIST)=BDD%XDESC_QIN_FRAD(DTT%NPAR_USETYPE(JLIST))
ENDIF
!
IF (PRESENT(PQIN_FLAT)) THEN
PQIN_FLAT(JLIST)=BDD%XDESC_QIN_FLAT(DTT%NPAR_USETYPE(JLIST))
ENDIF
!
IF (PRESENT(PMODQIN_VCD)) THEN
IF (SIZE(PMODQIN_VCD,2).EQ.1) THEN
PMODQIN_VCD(JLIST,1) = BDD%XDESC_MODQIN_VCD(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PMODQIN_VCD,2).EQ.6) THEN
PMODQIN_VCD(JLIST,1) = BDD%XDESC_MODQIN_VCD(DTT%NPAR_USETYPE(JLIST))
PMODQIN_VCD(JLIST,2) = BDD%XDESC_MODQIN_VCD(DTT%NPAR_USETYPE(JLIST))
PMODQIN_VCD(JLIST,3) = BDD%XDESC_MODQIN_VCD(DTT%NPAR_USETYPE(JLIST))
PMODQIN_VCD(JLIST,4) = BDD%XDESC_MODQIN_VCD(DTT%NPAR_USETYPE(JLIST))
PMODQIN_VCD(JLIST,5) = BDD%XDESC_MODQIN_VCD(BDD%NDESC_POS_USE_COM)
PMODQIN_VCD(JLIST,6) = BDD%XDESC_MODQIN_VCD(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PMODQIN_VLD)) THEN
IF (SIZE(PMODQIN_VLD,2).EQ.1) THEN
PMODQIN_VLD(JLIST,1) = BDD%XDESC_MODQIN_VLD(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PMODQIN_VLD,2).EQ.6) THEN
PMODQIN_VLD(JLIST,1) = BDD%XDESC_MODQIN_VLD(DTT%NPAR_USETYPE(JLIST))
PMODQIN_VLD(JLIST,2) = BDD%XDESC_MODQIN_VLD(DTT%NPAR_USETYPE(JLIST))
PMODQIN_VLD(JLIST,3) = BDD%XDESC_MODQIN_VLD(DTT%NPAR_USETYPE(JLIST))
PMODQIN_VLD(JLIST,4) = BDD%XDESC_MODQIN_VLD(DTT%NPAR_USETYPE(JLIST))
PMODQIN_VLD(JLIST,5) = BDD%XDESC_MODQIN_VLD(BDD%NDESC_POS_USE_COM)
PMODQIN_VLD(JLIST,6) = BDD%XDESC_MODQIN_VLD(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PMODQIN_NIG)) THEN
IF (SIZE(PMODQIN_NIG,2).EQ.1) THEN
PMODQIN_NIG(JLIST,1) = BDD%XDESC_MODQIN_NIG(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PMODQIN_NIG,2).EQ.6) THEN
PMODQIN_NIG(JLIST,1) = BDD%XDESC_MODQIN_NIG(DTT%NPAR_USETYPE(JLIST))
PMODQIN_NIG(JLIST,2) = BDD%XDESC_MODQIN_NIG(DTT%NPAR_USETYPE(JLIST))
PMODQIN_NIG(JLIST,3) = BDD%XDESC_MODQIN_NIG(DTT%NPAR_USETYPE(JLIST))
PMODQIN_NIG(JLIST,4) = BDD%XDESC_MODQIN_NIG(DTT%NPAR_USETYPE(JLIST))
PMODQIN_NIG(JLIST,5) = BDD%XDESC_MODQIN_NIG(BDD%NDESC_POS_USE_COM)
PMODQIN_NIG(JLIST,6) = BDD%XDESC_MODQIN_NIG(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PHOTWAT)) THEN
IF (SIZE(PHOTWAT,2).EQ.1) THEN
PHOTWAT(JLIST,1) = BDD%XDESC_HOTWAT(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PHOTWAT,2).EQ.6) THEN
PHOTWAT(JLIST,1) = BDD%XDESC_HOTWAT(DTT%NPAR_USETYPE(JLIST))
PHOTWAT(JLIST,2) = BDD%XDESC_HOTWAT(DTT%NPAR_USETYPE(JLIST))
PHOTWAT(JLIST,3) = BDD%XDESC_HOTWAT(DTT%NPAR_USETYPE(JLIST))
PHOTWAT(JLIST,4) = 0.0
PHOTWAT(JLIST,5) = 0.0
PHOTWAT(JLIST,6) = 0.0
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
ENDDO
!
! Initialisation of shading and ventilation-related variables
!
DO JLIST=1,SIZE(DTT%NPAR_USETYPE)
!
IF (PRESENT(PNATVENT)) THEN
IF (SIZE(PNATVENT,2).EQ.1) THEN
PNATVENT(JLIST,1) = BDD%XDESC_NATVENT(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PNATVENT,2).EQ.6) THEN
PNATVENT(JLIST,1) = BDD%XDESC_NATVENT(DTT%NPAR_USETYPE(JLIST))
PNATVENT(JLIST,2) = BDD%XDESC_NATVENT(DTT%NPAR_USETYPE(JLIST))
PNATVENT(JLIST,3) = BDD%XDESC_NATVENT(DTT%NPAR_USETYPE(JLIST))
PNATVENT(JLIST,4) = 0.0
PNATVENT(JLIST,5) = BDD%XDESC_NATVENT(BDD%NDESC_POS_USE_COM)
PNATVENT(JLIST,6) = BDD%XDESC_NATVENT(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PFVSUM)) THEN
IF (SIZE(PFVSUM,2).EQ.1) THEN
PFVSUM(JLIST,1) = BDD%XDESC_FVSUM(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PFVSUM,2).EQ.6) THEN
PFVSUM(JLIST,1) = BDD%XDESC_FVSUM(DTT%NPAR_USETYPE(JLIST))
PFVSUM(JLIST,2) = BDD%XDESC_FVSUM(DTT%NPAR_USETYPE(JLIST))
PFVSUM(JLIST,3) = BDD%XDESC_FVSUM(DTT%NPAR_USETYPE(JLIST))
PFVSUM(JLIST,4) = 0.0
PFVSUM(JLIST,5) = BDD%XDESC_FVSUM(BDD%NDESC_POS_USE_COM)
PFVSUM(JLIST,6) = BDD%XDESC_FVSUM(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PFVNIG)) THEN
IF (SIZE(PFVNIG,2).EQ.1) THEN
PFVNIG(JLIST,1) = BDD%XDESC_FVNIG(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PFVNIG,2).EQ.6) THEN
PFVNIG(JLIST,1) = BDD%XDESC_FVNIG(DTT%NPAR_USETYPE(JLIST))
PFVNIG(JLIST,2) = BDD%XDESC_FVNIG(DTT%NPAR_USETYPE(JLIST))
PFVNIG(JLIST,3) = BDD%XDESC_FVNIG(DTT%NPAR_USETYPE(JLIST))
PFVNIG(JLIST,4) = 0.0
PFVNIG(JLIST,5) = BDD%XDESC_FVNIG(BDD%NDESC_POS_USE_COM)
PFVNIG(JLIST,6) = BDD%XDESC_FVNIG(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PTDESV)) THEN
PTDESV(JLIST)=BDD%XDESC_TDESV(DTT%NPAR_USETYPE(JLIST))
ENDIF
!
IF (PRESENT(PFVVAC)) THEN
IF (SIZE(PFVVAC,2).EQ.1) THEN
PFVVAC(JLIST,1) = BDD%XDESC_FVVAC(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PFVVAC,2).EQ.6) THEN
PFVVAC(JLIST,1) = BDD%XDESC_FVVAC(DTT%NPAR_USETYPE(JLIST))
PFVVAC(JLIST,2) = BDD%XDESC_FVVAC(DTT%NPAR_USETYPE(JLIST))
PFVVAC(JLIST,3) = BDD%XDESC_FVVAC(DTT%NPAR_USETYPE(JLIST))
PFVVAC(JLIST,4) = 0.0
PFVVAC(JLIST,5) = BDD%XDESC_FVVAC(BDD%NDESC_POS_USE_COM)
PFVVAC(JLIST,6) = BDD%XDESC_FVVAC(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PFOPEN)) THEN
PFOPEN(JLIST)=BDD%XDESC_FOPEN(DTT%NPAR_USETYPE(JLIST))
ENDIF
!
IF (PRESENT(PFSSUM)) THEN
IF (SIZE(PFSSUM,2).EQ.1) THEN
PFSSUM(JLIST,1) = BDD%XDESC_FSSUM(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PFSSUM,2).EQ.6) THEN
PFSSUM(JLIST,1) = BDD%XDESC_FSSUM(DTT%NPAR_USETYPE(JLIST))
PFSSUM(JLIST,2) = BDD%XDESC_FSSUM(DTT%NPAR_USETYPE(JLIST))
PFSSUM(JLIST,3) = BDD%XDESC_FSSUM(DTT%NPAR_USETYPE(JLIST))
PFSSUM(JLIST,4) = 0.0
PFSSUM(JLIST,5) = BDD%XDESC_FSSUM(BDD%NDESC_POS_USE_COM)
PFSSUM(JLIST,6) = BDD%XDESC_FSSUM(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PFSNIG)) THEN
IF (SIZE(PFSNIG,2).EQ.1) THEN
PFSNIG(JLIST,1) = BDD%XDESC_FSNIG(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PFSNIG,2).EQ.6) THEN
PFSNIG(JLIST,1) = BDD%XDESC_FSNIG(DTT%NPAR_USETYPE(JLIST))
PFSNIG(JLIST,2) = BDD%XDESC_FSNIG(DTT%NPAR_USETYPE(JLIST))
PFSNIG(JLIST,3) = BDD%XDESC_FSNIG(DTT%NPAR_USETYPE(JLIST))
PFSNIG(JLIST,4) = 0.0
PFSNIG(JLIST,5) = BDD%XDESC_FSNIG(BDD%NDESC_POS_USE_COM)
PFSNIG(JLIST,6) = BDD%XDESC_FSNIG(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PFSVAC)) THEN
IF (SIZE(PFSVAC,2).EQ.1) THEN
PFSVAC(JLIST,1) = BDD%XDESC_FSVAC(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PFSVAC,2).EQ.6) THEN
PFSVAC(JLIST,1) = BDD%XDESC_FSVAC(DTT%NPAR_USETYPE(JLIST))
PFSVAC(JLIST,2) = BDD%XDESC_FSVAC(DTT%NPAR_USETYPE(JLIST))
PFSVAC(JLIST,3) = BDD%XDESC_FSVAC(DTT%NPAR_USETYPE(JLIST))
PFSVAC(JLIST,4) = 0.0
PFSVAC(JLIST,5) = BDD%XDESC_FSVAC(BDD%NDESC_POS_USE_COM)
PFSVAC(JLIST,6) = BDD%XDESC_FSVAC(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
ENDIF
!
IF (PRESENT(PWIN_SW_MAX)) THEN
PWIN_SW_MAX(JLIST)=BDD%XDESC_WIN_SW_MAX(DTT%NPAR_USETYPE(JLIST))
ENDIF
!
ENDDO
!
! Initialisation of building occupation-related variables
!
DO JLIST=1,SIZE(DTT%NPAR_USETYPE)
!
IF (PRESENT(PPROBOCC)) THEN
!
IF (SIZE(PPROBOCC,3).EQ.1) THEN
PPROBOCC(JLIST,:,1) = BDD%XDESC_PROBOCC(DTT%NPAR_USETYPE(JLIST),:)
ELSEIF (SIZE(PPROBOCC,3).EQ.6) THEN
PPROBOCC(JLIST,:,1) = BDD%XDESC_PROBOCC(DTT%NPAR_USETYPE(JLIST),:)
PPROBOCC(JLIST,:,2) = BDD%XDESC_PROBOCC(DTT%NPAR_USETYPE(JLIST),:)
PPROBOCC(JLIST,:,3) = BDD%XDESC_PROBOCC(DTT%NPAR_USETYPE(JLIST),:)
PPROBOCC(JLIST,:,4) = 0.0
PPROBOCC(JLIST,:,5) = BDD%XDESC_PROBOCC(BDD%NDESC_POS_USE_COM,:)
PPROBOCC(JLIST,:,6) = BDD%XDESC_PROBOCC(BDD%NDESC_POS_USE_TER,:)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
!
IF (MAXVAL(PPROBOCC(JLIST,:,:)).GT.1.0) CALL ABOR1_SFX ("Wrong building occuppation probability")
IF (MINVAL(PPROBOCC(JLIST,:,:)).LT.0.0) CALL ABOR1_SFX ("Wrong building occuppation probability")
!
ENDIF
!
! Initialisation of schedules
!
IF (PRESENT(PDAYWBEG_SCHED)) THEN
!
IF (SIZE(PDAYWBEG_SCHED,3).EQ.1) THEN
PDAYWBEG_SCHED(JLIST,:,1) = BDD%XDESC_DAYWBEG_SCHED(DTT%NPAR_USETYPE(JLIST),:)
ELSEIF (SIZE(PDAYWBEG_SCHED,3).EQ.6) THEN
PDAYWBEG_SCHED(JLIST,:,1) = BDD%XDESC_DAYWBEG_SCHED(DTT%NPAR_USETYPE(JLIST),:)
PDAYWBEG_SCHED(JLIST,:,2) = BDD%XDESC_DAYWBEG_SCHED(DTT%NPAR_USETYPE(JLIST),:)
PDAYWBEG_SCHED(JLIST,:,3) = BDD%XDESC_DAYWBEG_SCHED(DTT%NPAR_USETYPE(JLIST),:)
PDAYWBEG_SCHED(JLIST,:,4) = BDD%XDESC_DAYWBEG_SCHED(DTT%NPAR_USETYPE(JLIST),:)
PDAYWBEG_SCHED(JLIST,:,5) = BDD%XDESC_DAYWBEG_SCHED(BDD%NDESC_POS_USE_COM,:)
PDAYWBEG_SCHED(JLIST,:,6) = BDD%XDESC_DAYWBEG_SCHED(BDD%NDESC_POS_USE_TER,:)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
!
ENDIF
!
IF (PRESENT(PHOURBEG_SCHED)) THEN
!
IF (SIZE(PHOURBEG_SCHED,3).EQ.1) THEN
PHOURBEG_SCHED(JLIST,:,1) = BDD%XDESC_HOURBEG_SCHED(DTT%NPAR_USETYPE(JLIST),:)
ELSEIF (SIZE(PHOURBEG_SCHED,3).EQ.6) THEN
PHOURBEG_SCHED(JLIST,:,1) = BDD%XDESC_HOURBEG_SCHED(DTT%NPAR_USETYPE(JLIST),:)
PHOURBEG_SCHED(JLIST,:,2) = BDD%XDESC_HOURBEG_SCHED(DTT%NPAR_USETYPE(JLIST),:)
PHOURBEG_SCHED(JLIST,:,3) = BDD%XDESC_HOURBEG_SCHED(DTT%NPAR_USETYPE(JLIST),:)
PHOURBEG_SCHED(JLIST,:,4) = BDD%XDESC_HOURBEG_SCHED(DTT%NPAR_USETYPE(JLIST),:)
PHOURBEG_SCHED(JLIST,:,5) = BDD%XDESC_HOURBEG_SCHED(BDD%NDESC_POS_USE_COM,:)
PHOURBEG_SCHED(JLIST,:,6) = BDD%XDESC_HOURBEG_SCHED(BDD%NDESC_POS_USE_TER,:)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
!
ENDIF
!
! Initialisation of holidays
!
IF (PRESENT(PBEG_HOLIDAY)) THEN
!
IF (SIZE(PBEG_HOLIDAY,3).EQ.1) THEN
PBEG_HOLIDAY(JLIST,:,1) = BDD%XDESC_BEG_HOLIDAY(DTT%NPAR_USETYPE(JLIST),:)
ELSEIF (SIZE(PBEG_HOLIDAY,3).EQ.6) THEN
PBEG_HOLIDAY(JLIST,:,1) = BDD%XDESC_BEG_HOLIDAY(DTT%NPAR_USETYPE(JLIST),:)
PBEG_HOLIDAY(JLIST,:,2) = BDD%XDESC_BEG_HOLIDAY(DTT%NPAR_USETYPE(JLIST),:)
PBEG_HOLIDAY(JLIST,:,3) = BDD%XDESC_BEG_HOLIDAY(DTT%NPAR_USETYPE(JLIST),:)
PBEG_HOLIDAY(JLIST,:,4) = BDD%XDESC_BEG_HOLIDAY(DTT%NPAR_USETYPE(JLIST),:)
PBEG_HOLIDAY(JLIST,:,5) = BDD%XDESC_BEG_HOLIDAY(BDD%NDESC_POS_USE_COM,:)
PBEG_HOLIDAY(JLIST,:,6) = BDD%XDESC_BEG_HOLIDAY(BDD%NDESC_POS_USE_TER,:)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
!
ENDIF
!
IF (PRESENT(PEND_HOLIDAY)) THEN
!
IF (SIZE(PEND_HOLIDAY,3).EQ.1) THEN
PEND_HOLIDAY(JLIST,:,1) = BDD%XDESC_END_HOLIDAY(DTT%NPAR_USETYPE(JLIST),:)
ELSEIF (SIZE(PEND_HOLIDAY,3).EQ.6) THEN
PEND_HOLIDAY(JLIST,:,1) = BDD%XDESC_END_HOLIDAY(DTT%NPAR_USETYPE(JLIST),:)
PEND_HOLIDAY(JLIST,:,2) = BDD%XDESC_END_HOLIDAY(DTT%NPAR_USETYPE(JLIST),:)
PEND_HOLIDAY(JLIST,:,3) = BDD%XDESC_END_HOLIDAY(DTT%NPAR_USETYPE(JLIST),:)
PEND_HOLIDAY(JLIST,:,4) = BDD%XDESC_END_HOLIDAY(DTT%NPAR_USETYPE(JLIST),:)
PEND_HOLIDAY(JLIST,:,5) = BDD%XDESC_END_HOLIDAY(BDD%NDESC_POS_USE_COM,:)
PEND_HOLIDAY(JLIST,:,6) = BDD%XDESC_END_HOLIDAY(BDD%NDESC_POS_USE_TER,:)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
!
ENDIF
!
IF (PRESENT(PMOD_HOLIDAY)) THEN
!
IF (SIZE(PMOD_HOLIDAY,2).EQ.1) THEN
PMOD_HOLIDAY(JLIST,1) = BDD%XDESC_MOD_HOLIDAY(DTT%NPAR_USETYPE(JLIST))
ELSEIF (SIZE(PMOD_HOLIDAY,2).EQ.6) THEN
PMOD_HOLIDAY(JLIST,1) = BDD%XDESC_MOD_HOLIDAY(DTT%NPAR_USETYPE(JLIST))
PMOD_HOLIDAY(JLIST,2) = BDD%XDESC_MOD_HOLIDAY(DTT%NPAR_USETYPE(JLIST))
PMOD_HOLIDAY(JLIST,3) = BDD%XDESC_MOD_HOLIDAY(DTT%NPAR_USETYPE(JLIST))
PMOD_HOLIDAY(JLIST,4) = BDD%XDESC_MOD_HOLIDAY(DTT%NPAR_USETYPE(JLIST))
PMOD_HOLIDAY(JLIST,5) = BDD%XDESC_MOD_HOLIDAY(BDD%NDESC_POS_USE_COM)
PMOD_HOLIDAY(JLIST,6) = BDD%XDESC_MOD_HOLIDAY(BDD%NDESC_POS_USE_TER)
ELSE
CALL ABOR1_SFX ("No rule for this number of compartments")
ENDIF
!
ENDIF
!
ENDDO
!
IF (LHOOK) CALL DR_HOOK('INI_DATA_PARAM_TEB',1,ZHOOK_HANDLE)
!-------------------------------------------------------------------------------
!
END SUBROUTINE INI_DATA_PARAM_TEB