Jean W. 18/07/2024: SURFEX add init of old pressure to actual pressure....

Jean W. 18/07/2024: SURFEX add init of old pressure to actual pressure. Previous pressure is used in BEM but is default is wrong leading to possible crash at first timestep.
parent c05c8cdb
No related branches found
No related tags found
No related merge requests found
...@@ -1061,6 +1061,14 @@ DO JP = 1,TOP%NTEB_PATCH ...@@ -1061,6 +1061,14 @@ DO JP = 1,TOP%NTEB_PATCH
CALL ABOR1_SFX("COUPLING_TEBN: Negative humidity in canyon") CALL ABOR1_SFX("COUPLING_TEBN: Negative humidity in canyon")
ENDIF ENDIF
! !
!CHECK if old pressure is initialized
IF (ANY(NB%AL(JP)%XPSOLD(:)==XUNDEF)) THEN
NB%AL(JP)%XPSOLD(:)=PPS(:)
END IF
CALL TOWN_ENERGY_BALANCE(DTCO, G, TOP, SPAOP, NT%AL(JP), BOP, NB%AL(JP), TPN, TIR, TD%NDMT%AL(JP), GDM, GRM, & CALL TOWN_ENERGY_BALANCE(DTCO, G, TOP, SPAOP, NT%AL(JP), BOP, NB%AL(JP), TPN, TIR, TD%NDMT%AL(JP), GDM, GRM, &
HM, SB, CT, JP, HPROGRAM, CIMPLICIT_WIND, PTSUN, ZT_CAN, ZQ_CAN, ZU_CANYON, ZT_LOWCAN, & HM, SB, CT, JP, HPROGRAM, CIMPLICIT_WIND, PTSUN, ZT_CAN, ZQ_CAN, ZU_CANYON, ZT_LOWCAN, &