Skip to content
Snippets Groups Projects
Commit af5a4753 authored by Pierre Tulet's avatar Pierre Tulet
Browse files

P.Tulet 22/02/23: correction du calcul de la viscosité pour SST <283.15 et SST...

P.Tulet 22/02/23: correction du calcul de la viscosité pour SST <283.15 et SST > 303.15.  correction of the viscosity calculation for SST <283.15 and SST > 303.15.
parent f3be929f
No related branches found
No related tags found
No related merge requests found
......@@ -192,7 +192,7 @@ IF ((CEMISPARAM_SLT .eq. "Ova14").OR.(CEMISPARAM_SLT .eq. "OvB21a").OR.(CEMISPAR
! Tableau d'interpolation pour calculer ZNUWATER en fonction de la SST
! Cas ou 0 < SST < 10 C
WHERE ((PSST(:) >= 273.15).AND.(PSST(:) < 283.15))
WHERE (PSST(:) < 283.15)
ZVISCO(:) = ZNUWATER(1) + (PSST(:) - ZWT(1)) * (ZNUWATER(2)-ZNUWATER(1)) / &
(ZWT(2) - ZWT(1))
ENDWHERE
......@@ -210,7 +210,7 @@ IF ((CEMISPARAM_SLT .eq. "Ova14").OR.(CEMISPARAM_SLT .eq. "OvB21a").OR.(CEMISPAR
ENDWHERE
! Cas ou 30 < SST < 40 C
WHERE ((PSST(:) >= 303.15).AND.(PSST(:) < 313.15))
WHERE (PSST(:) >= 303.15)
ZVISCO(:) = ZNUWATER(4) + (PSST(:) - ZWT(4)) * (ZNUWATER(5)-ZNUWATER(4)) / &
(ZWT(5) - ZWT(4))
ENDWHERE
......
0% Loading or .