Skip to content
Snippets Groups Projects
ini_data_param_teb.F90 68.9 KiB
Newer Older
!SFX_LIC Copyright 1994-2014 CNRS, Meteo-France and Universite Paul Sabatier
!SFX_LIC This is part of the SURFEX software governed by the CeCILL-C licence
!SFX_LIC version 1. See LICENSE, CeCILL-C_V1-en.txt and CeCILL-C_V1-fr.txt  
!SFX_LIC for details. version 1.
!     #########################
      SUBROUTINE INI_DATA_PARAM_TEB(HPROGRAM, BDD, DTT, KTYPE, PFLOOR_HEIGHT,                     &
                              PCAP_SYS_HEAT, PCAP_SYS_RAT, PT_ADP, PM_SYS_RAT,              &
                              PT_SIZE_MAX, PT_SIZE_MIN, PROUGH_ROOF, PROUGH_WALL,           &
                              PALB_ROOF, PEMIS_ROOF, PHC_ROOF, PTC_ROOF, PD_ROOF,           & 
                              PALB_WALL, PEMIS_WALL, PHC_WALL, PTC_WALL, PD_WALL,           &
                              NISOROOFPOS, NISOWALLPOS, PALB_ROAD, PEMIS_ROAD, PHC_ROAD, PTC_ROAD, PD_ROAD, &
                              PHC_FLOOR, PTC_FLOOR, PD_FLOOR, PISMASS, PHC_MASS, PTC_MASS,  &
                              PD_MASS, PN50,PGR,PU_WIN,PSHGC,PSHGC_SH,PSHADEARCHI,          &
                              PISMECH,PMECHRATE,PGREENROOF,                                 &
                              PEMIS_PANEL,PALB_PANEL,PEFF_PANEL,                            &
                              PFRAC_PANEL, PTHEAT_OCCD,PTHEAT_OCCN,PTHEAT_VCDD,PTHEAT_VCDN, &
                              PTHEAT_VCLD,PFRACOMP,PTCOOL_OCCD,PTCOOL_OCCN,PTCOOL_VCDD,PTCOOL_VCDN,&
                              PTCOOL_VCLD,PF_WATER_COND,PCOP_RAT,PHR_TARGET,PQIN,PQIN_FRAD, &
                              PQIN_FLAT,PMODQIN_VCD,PMODQIN_VLD,PMODQIN_NIG,PHOTWAT,PNATVENT,PFVSUM,PFVNIG, &
                              PTDESV,PFVVAC,PFOPEN,PFSSUM,PFSNIG,PFSVAC,PWIN_SW_MAX,PDAYWBEG_SCHED,         &
                              PHOURBEG_SCHED,PBEG_HOLIDAY,PEND_HOLIDAY,PMOD_HOLIDAY,PPROBOCC,PF_WASTE_CAN)

!     #########################
!
!!
!!    PURPOSE
!!    -------
!!
!!    METHOD
!!    ------
!!
!!
!!    EXTERNAL
!!    --------
!!
!!    IMPLICIT ARGUMENTS
!!    ------------------
!!
!!    REFERENCE
!!    ---------
!!
!!    AUTHOR
!!    ------
!!
!!    S. Faroux & V. Masson        Meteo-France
!!
!!    MODIFICATION
!!    ------------
!!
!!    Original    05/2012 from INI_DATA_PARAM_TEB, separates urban parameters
!!    modified    08/2012 add PROUGH_ROOF, PROUGH_WALL
!!     V. Masson  08/2013 add solar panels
!!     R. Schoetter 11/2015 Major changes in order to read MApUCE data
!----------------------------------------------------------------------------
!
!*    0.     DECLARATION
!            -----------
!
USE MODD_BLD_DESCRIPTION_n, ONLY : BLD_DESC_t
USE MODD_DATA_TEB_n, ONLY : DATA_TEB_t
USE MODD_CSTS, ONLY : XSURF_EPSILON
!
USE MODI_ABOR1_SFX
!
USE YOMHOOK   ,ONLY : LHOOK,   DR_HOOK
USE PARKIND1  ,ONLY : JPRB
!
IMPLICIT NONE
!
!*    0.1    Declaration of arguments
!            ------------------------
!
TYPE(BLD_DESC_t), INTENT(INOUT) :: BDD
TYPE(DATA_TEB_t), INTENT(INOUT) :: DTT
INTEGER, DIMENSION(:), INTENT(INOUT) :: KTYPE
 CHARACTER(LEN=6),    INTENT(IN)  :: HPROGRAM  ! program calling surf. schemes
!
! Parameters not yet read from tables
!
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PFLOOR_HEIGHT
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PCAP_SYS_HEAT
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PCAP_SYS_RAT
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PT_ADP
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PM_SYS_RAT
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PT_SIZE_MAX
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PT_SIZE_MIN
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PROUGH_ROOF
REAL, DIMENSION(:), INTENT(OUT), OPTIONAL :: PROUGH_WALL
!
! Building architectural characteristics
!
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PALB_ROOF
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PEMIS_ROOF
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PHC_ROOF
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTC_ROOF
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PD_ROOF
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PALB_WALL
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PEMIS_WALL
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PHC_WALL
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTC_WALL
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PD_WALL
INTEGER, DIMENSION(:),   INTENT(OUT), OPTIONAL :: NISOROOFPOS
INTEGER, DIMENSION(:),   INTENT(OUT), OPTIONAL :: NISOWALLPOS
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PALB_ROAD
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PEMIS_ROAD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PHC_ROAD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTC_ROAD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PD_ROAD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PHC_FLOOR
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTC_FLOOR
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PD_FLOOR
REAL, DIMENSION(:)  , INTENT(OUT), OPTIONAL :: PISMASS
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PHC_MASS
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTC_MASS
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PD_MASS
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PN50
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PGR
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PU_WIN
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PSHGC
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PSHGC_SH
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PSHADEARCHI
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PISMECH
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PMECHRATE
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PGREENROOF
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PEMIS_PANEL
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PALB_PANEL
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PEFF_PANEL
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PFRAC_PANEL
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PF_WASTE_CAN
!
! Occupant behaviour characteristics
!
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTHEAT_OCCD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTHEAT_OCCN
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTHEAT_VCDD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTHEAT_VCDN
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTHEAT_VCLD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFRACOMP
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTCOOL_OCCD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTCOOL_OCCN
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTCOOL_VCDD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTCOOL_VCDN
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PTCOOL_VCLD
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PF_WATER_COND
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PCOP_RAT
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PHR_TARGET
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PQIN
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PQIN_FRAD
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PQIN_FLAT
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PMODQIN_VCD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PMODQIN_VLD
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PMODQIN_NIG
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PHOTWAT
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PNATVENT
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFVSUM
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFVNIG
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PTDESV
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFVVAC
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PFOPEN
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFSSUM
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFSNIG
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL :: PFSVAC
REAL, DIMENSION(:),   INTENT(OUT), OPTIONAL :: PWIN_SW_MAX
REAL, DIMENSION(:,:,:), INTENT(OUT), OPTIONAL :: PBEG_HOLIDAY
REAL, DIMENSION(:,:,:), INTENT(OUT), OPTIONAL :: PEND_HOLIDAY
REAL, DIMENSION(:,:), INTENT(OUT), OPTIONAL   :: PMOD_HOLIDAY
REAL, DIMENSION(:,:,:), INTENT(OUT), OPTIONAL :: PDAYWBEG_SCHED
REAL, DIMENSION(:,:,:), INTENT(OUT), OPTIONAL :: PHOURBEG_SCHED
REAL, DIMENSION(:,:,:), INTENT(OUT), OPTIONAL :: PPROBOCC
!
!*    0.2    Declaration of local variables
!      ------------------------------
!
INTEGER, DIMENSION(:), ALLOCATABLE :: ILIST ! link between urban types and indices
INTEGER            :: JLOOP        ! spatial loop counter
INTEGER            :: JLIST        ! loop counter on urban types
INTEGER            :: KLIST        ! loop counter on urban types
INTEGER            :: IINDEX       ! index of type for each point
INTEGER            :: NCTL         ! Control variable
INTEGER            :: ILUOUT       ! Unit number
!
REAL(KIND=JPRB) :: ZHOOK_HANDLE
!
!-------------------------------------------------------------------------------
!-------------------------------------------------------------------------------
!
IF (LHOOK) CALL DR_HOOK('INI_DATA_PARAM_TEB',0,ZHOOK_HANDLE)
!
!-------------------------------------------------------------------------------
!
!*    1.     Builds the list of indices corresponding to the "type" field
!      ------------------------------------------------------------------
!
196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745
ALLOCATE(ILIST(SIZE(KTYPE)))
ILIST(:) = -9999
!
! ##################################################################
! Elimination of unrealistic combinations of input data
! This is only valid for MApUCE data, and an alternative
! is required for other input datasets.
! ##################################################################
!
DO JLIST=1,SIZE(KTYPE)
  !
  ! A) In the case the building type is "high-rise building" and the
  !    construction period is P1, the construction period is set
  !    to P2, since there are no high-rise buildings in P1.
  !
  IF ((DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_BGH).AND.(DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1)) THEN
     !
     DTT%NPAR_COL_BLD_AGE(JLIST)=BDD%NDESC_POS_AGE_P2
     !
     CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
          DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     !
  ENDIF
  !
  ! B) In the case the building type is "local", the use is set to "LOCAL NON CHAUFFE"
  !
  IF (DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_LOCA) THEN
     !
     DTT%NPAR_USETYPE(JLIST)=BDD%NDESC_POS_USE_LNC
     !
     IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ELSE
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ENDIF
     !
  ENDIF
  !
  ! C) In the case the building type coincides with individual housing, but the
  !    use with collective housing, the use is set to individual housing
  !    The building type is given priority
  !
  IF ( ((DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_PD)  .OR.(DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_PSC).OR. &
        (DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_PCIO).OR.(DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_PCIF)) .AND. &
        (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAC) )  THEN
     !
     DTT%NPAR_USETYPE(JLIST)=BDD%NDESC_POS_USE_HAI
     !
     IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ELSE
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ENDIF
     !
  ENDIF
  !
  ! D) In the case the building type coincides with collective housing, but the
  !    use is INDIVIDUEL, the use is set to COLLECTIF
  !    The building type is given priority
  !
  IF ( ((DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_ID).OR.(DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_ICIO).OR. &
        (DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_ICIF)).AND.(DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAI)) THEN
     !
     DTT%NPAR_USETYPE(JLIST)=BDD%NDESC_POS_USE_HAC
     !
     IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ELSE
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ENDIF
     !
  ENDIF
  !
  ! E) In the case the building type is "BATIMENT D'ACTIVITE",
  !    but the use is INDIVIDUEL or COLLECTIF it is set to INDUSTRIEL
  !    The building type is given priority
  !
  IF ( ((DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAC).OR.(DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAI)) .AND. &
        (DTT%NPAR_BLDTYPE(JLIST).EQ.BDD%NDESC_POS_TYP_BA) )  THEN
     !
     DTT%NPAR_USETYPE(JLIST)=BDD%NDESC_POS_USE_IND
     !
     IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ELSE
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ENDIF
     !
  ENDIF
  !
  ! F) In the case the use is LOCAL NON CHAUFFE, the building type is set to "LOCAL"
  !
  IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_LNC) THEN
     !
     DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_LOCA
     !
     IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ELSE
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ENDIF
     !
  ENDIF
  !
  ! G) For Office use, the building type must be ID/ICIO/ICIF/ for P1 and ID/ICIO/BGH for PX
  !
  IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_TER) THEN
     !
     IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
        !
        IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIO).AND. &
            (DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF)) THEN
           !
           DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIO
           !
           CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST), &
                DTT%NPAR_USETYPE(JLIST),DTT%NPAR_P1TERRITORY(JLIST), &
                DTT%NPAR_BLDCODE(JLIST))
           !
        ENDIF
        !
     ELSE
        !
        IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIO).AND. &
            (DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_BGH)) THEN
           !
           DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIO
           !
           CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST), &
                DTT%NPAR_USETYPE(JLIST),DTT%NPAR_PXTERRITORY(JLIST), &
                DTT%NPAR_BLDCODE(JLIST))
           !
        ENDIF
        !
     ENDIF
     !
  ENDIF
  !
  ! H) In the case the use is SANTE and the building type is not ICIF or ICIO, the building type is set to ICIO.
  !
  IF ( (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_SAN).AND. &
      ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIO)) )  THEN
      !
      DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIO
      !
      IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
         CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
              DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
      ELSE
         CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
              DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
      ENDIF
      !
  ENDIF
  !
  ! I) In the case the use is ENSEIGNEMENT and the building type 
  !    is not ID/ICIO/ICIF the building type is set to ICIO.
  !
  IF ( (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_ENS).AND. &
       ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIO).AND. &
        (DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF))) THEN
      !
      DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIO
      !
      IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
         CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
              DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
      ELSE
         CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
              DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
      ENDIF
      !
   ENDIF
   !
   ! K) In the case the use is CHATEAU the building type must be ID and the period must be P1
   !
   IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_CHA) THEN
     !
     DTT%NPAR_BLDTYPE(JLIST)     = BDD%NDESC_POS_TYP_ID
     DTT%NPAR_COL_BLD_AGE(JLIST) = BDD%NDESC_POS_AGE_P1
     DTT%NPAR_IND_BLD_AGE(JLIST) = BDD%NDESC_POS_AGE_P1
     !
     CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
                  DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     !
  ENDIF
  !
  ! L) In the case the use is SPORTIF the building type must be BA
  !
  IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_SPO) THEN
     !
     DTT%NPAR_BLDTYPE(JLIST) = BDD%NDESC_POS_TYP_BA
     !
     IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ELSE
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ENDIF
     !
  ENDIF
  !
  ! M) In the case the use is RELIGIEUX the building type must be ID/ICIF
  !
  IF ( (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_REL) .AND. &
      ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF)) ) THEN
      !
      DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIF
      !
      IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
         CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
      ELSE
         CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
      ENDIF
      !
  ENDIF
  !
  ! N) In the case the use is AGRICOLE the building type must be BA
  !
  IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_AGR)  THEN
     !
     DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_BA
     !
     IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ELSE
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ENDIF
     !
  ENDIF
  !
  ! O) In the case the use is SERRE the building type must be BA
  !
  IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_SER)  THEN
     !
     DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_BA
     !
     IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ELSE
        CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
             DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
     ENDIF
     !
  ENDIF
  !
  ! P) In the case the use is INDUSTRIEL the building type must be BA
  !
  IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_IND)  THEN
      !
      DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_BA
      !
      IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
         CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
              DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
      ELSE
         CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
              DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
      ENDIF
      !
   ENDIF
   !
   ! Q) In the case the use is COMMERCE the building type must be 
   !    ID/ICIO/ICIF for P1
   !    ID/ICIF for P2 to P3
   !    ID/ICIF/BA for P4 to P7 and ID/ICIF for P1 to P3
   !
   IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_COM) THEN
      !
      IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
         !
         IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF).AND. &
            (DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIO)) THEN
            !
            DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIF
            !
            CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
                         DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
            !
         ENDIF
         !
      ELSEIF (DTT%NPAR_COL_BLD_AGE(JLIST).LT.BDD%NDESC_POS_AGE_P4) THEN
         !
         IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF)) THEN
            !
            DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIF
            !
            CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
                         DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
            !
         ENDIF
         !
      ELSE
         !
         IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF).AND. &
             (DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_BA)) THEN
            !
            DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_BA
            !
            CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
                         DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
            !
         ENDIF
         !
      ENDIF
      !
   ENDIF
   !
   ! R) In the case the use is COLLECTIF the building type must be ID/ICIO/ICIF/BGH
   !
   IF ( (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAC) .AND. &
       ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ID)  .AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIO).AND. &
        (DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_ICIF).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_BGH) ) )  THEN
      !
      DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_ICIO
      !
      IF (DTT%NPAR_COL_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
         CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
              DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
      ELSE
         CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
              DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
      ENDIF
      !
   ENDIF
   !
   ! S) In the case the use is INDIVIDUEL the building type must be PD/PSC/PCIO/PCIF
   !
   IF ( (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAI) .AND. &
       ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PD)  .AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PSC).AND. &
       (DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIO).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIF) ))  THEN
       !
       DTT%NPAR_BLDTYPE(JLIST)=BDD%NDESC_POS_TYP_PD
       !
       IF (DTT%NPAR_IND_BLD_AGE(JLIST).EQ.BDD%NDESC_POS_AGE_P1) THEN
          CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
               DTT%NPAR_P1TERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
       ELSE
          CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
               DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
       ENDIF
       !
   ENDIF
   !
ENDDO
!
! ##################################################################
! Treatment of missing combinations of building type,
! use, construction period and territory
! ##################################################################
!
DO JLIST=1,SIZE(KTYPE)
   !
   ! Test matching of initial building code
   !
   KTYPE(JLIST)=DTT%NPAR_BLDCODE(JLIST)
   !
   NCTL=0
   DO KLIST=1,SIZE(BDD%NDESC_CODE_LIST)
      IF (KTYPE(JLIST).EQ.BDD%NDESC_CODE_LIST(KLIST)) THEN
         ILIST(JLIST) = KLIST
         NCTL=NCTL+1
      ENDIF
   END DO
   !
   ! There must only be one line in the .csv-table corresponding
   ! to the given building code
   !
   IF (NCTL.GT.1) CALL ABOR1_SFX("More than one line in csv-file corresponds to input")
   !
   ! Treatment of missing data
   !
   IF (NCTL.EQ.0) THEN
      !
      ! If the construction period is larger than 1, the territory is set to default
      !
      IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PD)  .AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PSC).AND. &
          (DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIO).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIF)) THEN
         !
         IF (DTT%NPAR_COL_BLD_AGE(JLIST).NE.BDD%NDESC_POS_AGE_P1) THEN
            !
            DTT%NPAR_PXTERRITORY(JLIST)=BDD%NDESC_POS_PX_DEFAULT
            !
            CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
                 DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
            !
            KTYPE(JLIST)=DTT%NPAR_BLDCODE(JLIST)
            !
         ENDIF
         !
      ELSE
         !
         IF (DTT%NPAR_IND_BLD_AGE(JLIST).NE.BDD%NDESC_POS_AGE_P1) THEN
            !
            DTT%NPAR_PXTERRITORY(JLIST)=BDD%NDESC_POS_PX_DEFAULT
            !
            CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
                 DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
            !
            KTYPE(JLIST)=DTT%NPAR_BLDCODE(JLIST)
            !
         ENDIF
         !
      ENDIF
      !
      ! Test matching of modified building code
      !
      NCTL=0
      DO KLIST=1,SIZE(BDD%NDESC_CODE_LIST)
         IF (KTYPE(JLIST).EQ.BDD%NDESC_CODE_LIST(KLIST)) THEN
            ILIST(JLIST) = KLIST
            NCTL=NCTL+1
         ENDIF
      ENDDO
      IF (NCTL.GT.1) CALL ABOR1_SFX("More than one line in csv-file corresponds to input")
      !
      IF (NCTL.EQ.0) THEN
         !
         ! In case of still missing arcitectural description,
         ! the constuction period is increased until a match is found.
         ! It is assmed, that the construction period numbering
         ! increases towards more recent periods
         !
         DO 
            !
            IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PD)  .AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PSC).AND. &
                (DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIO).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIF)) THEN
               !
               IF (DTT%NPAR_COL_BLD_AGE(JLIST).NE.BDD%NDESC_POS_AGE_P7) THEN
                  !
                  DTT%NPAR_COL_BLD_AGE(JLIST)=DTT%NPAR_COL_BLD_AGE(JLIST)+1
                  !
                  CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
                       DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
                  !
                  KTYPE(JLIST)=DTT%NPAR_BLDCODE(JLIST)
                  !
               ELSE
                  CALL GET_LUOUT(HPROGRAM,ILUOUT)
                  WRITE(ILUOUT,*) "                                                          "
                  WRITE(ILUOUT,*) "In ini_data_param_teb                                     "
                  WRITE(ILUOUT,*) "No building archetype found for the following combination "
                  WRITE(ILUOUT,*) "of building type, use, construction period and territory  "
                  WRITE(ILUOUT,*) "                            "
                  WRITE(ILUOUT,*) "DTT%NPAR_BLDTYPE(JLIST)     ",DTT%NPAR_BLDTYPE(JLIST)
                  WRITE(ILUOUT,*) "DTT%NPAR_COL_BLD_AGE(JLIST) ",DTT%NPAR_COL_BLD_AGE(JLIST)
                  WRITE(ILUOUT,*) "DTT%NPAR_USETYPE(JLIST)     ",DTT%NPAR_USETYPE(JLIST)
                  WRITE(ILUOUT,*) "DTT%NPAR_PXTERRITORY(JLIST) ",DTT%NPAR_PXTERRITORY(JLIST)
                  CALL FLUSH(ILUOUT)
                  CALL ABOR1_SFX ("Missing building archetype, check report")
               ENDIF
               !
            ELSE
               !
               IF (DTT%NPAR_IND_BLD_AGE(JLIST).NE.BDD%NDESC_POS_AGE_P7) THEN
                  !
                  DTT%NPAR_IND_BLD_AGE(JLIST)=DTT%NPAR_IND_BLD_AGE(JLIST)+1
                  !
                  CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
                       DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
                  !
                  KTYPE(JLIST)=DTT%NPAR_BLDCODE(JLIST)
                  !
               ELSE
                  CALL GET_LUOUT(HPROGRAM,ILUOUT)
                  WRITE(ILUOUT,*) "                                                          "
                  WRITE(ILUOUT,*) "In ini_data_param_teb                                     "
                  WRITE(ILUOUT,*) "No building archetype found for the following combination "
                  WRITE(ILUOUT,*) "of building type, use, construction period and territory  "
                  WRITE(ILUOUT,*) "                            "
                  WRITE(ILUOUT,*) "DTT%NPAR_BLDTYPE(JLIST)     ",DTT%NPAR_BLDTYPE(JLIST)
                  WRITE(ILUOUT,*) "DTT%NPAR_IND_BLD_AGE(JLIST) ",DTT%NPAR_IND_BLD_AGE(JLIST)
                  WRITE(ILUOUT,*) "DTT%NPAR_USETYPE(JLIST)     ",DTT%NPAR_USETYPE(JLIST)
                  WRITE(ILUOUT,*) "DTT%NPAR_PXTERRITORY(JLIST) ",DTT%NPAR_PXTERRITORY(JLIST)
                  CALL FLUSH(ILUOUT)
                  CALL ABOR1_SFX ("Missing building archetype, check report")
               ENDIF
               !
            ENDIF
            !
            ! Test matching of modified building code
            !
            NCTL=0
            DO KLIST=1,SIZE(BDD%NDESC_CODE_LIST)
               IF (KTYPE(JLIST).EQ.BDD%NDESC_CODE_LIST(KLIST)) THEN
                  ILIST(JLIST) = KLIST
                  NCTL=NCTL+1
               ENDIF
            ENDDO
            !
            IF (NCTL.GT.0) THEN
               EXIT
            ENDIF
            !
            ! Set territory to default
            !
            DTT%NPAR_PXTERRITORY(JLIST)=BDD%NDESC_POS_PX_DEFAULT
            !
            IF ((DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PD)  .AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PSC).AND.&
               (DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIO).AND.(DTT%NPAR_BLDTYPE(JLIST).NE.BDD%NDESC_POS_TYP_PCIF)) THEN
               CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_COL_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
                    DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
            ELSE
               CALL BLDCODE(DTT%NPAR_BLDTYPE(JLIST),DTT%NPAR_IND_BLD_AGE(JLIST),DTT%NPAR_USETYPE(JLIST), &
                    DTT%NPAR_PXTERRITORY(JLIST),DTT%NPAR_BLDCODE(JLIST))
            ENDIF
            !
            KTYPE(JLIST)=DTT%NPAR_BLDCODE(JLIST)
            !
            ! Test matching of modified building code
            !
            NCTL=0
            DO KLIST=1,SIZE(BDD%NDESC_CODE_LIST)
               IF (KTYPE(JLIST).EQ.BDD%NDESC_CODE_LIST(KLIST)) THEN
                  ILIST(JLIST) = KLIST
                  NCTL=NCTL+1
               ENDIF
            ENDDO
            !
            IF (NCTL.GT.0) THEN
               EXIT
            ENDIF
            !
         ENDDO
         !
      ENDIF
      !
   ENDIF
   !
ENDDO
!
! ###########################################################
! Initialisation of architectural characteristics 
! ###########################################################
!
IINDEX = 0
!
!-------------------------------------------------------------------------------
DO JLOOP=1,SIZE(KTYPE)
!-------------------------------------------------------------------------------
!
!*    1.     town parameters depending on urban characteristics
!      --------------------------------------------------------
!
    IF (PRESENT(PALB_ROAD)) THEN
      PALB_ROAD(JLOOP)=BDD%XDESC_ALB_ROAD(IINDEX)
    ENDIF
    IF (PRESENT(PEMIS_ROAD)) THEN
      PEMIS_ROAD(JLOOP)=BDD%XDESC_EMIS_ROAD(IINDEX)
    ENDIF
    IF (PRESENT(PHC_ROAD)) THEN
      PHC_ROAD(JLOOP,:)= BDD%XDESC_HC_ROAD(IINDEX,:)
    ENDIF
    IF (PRESENT(PTC_ROAD)) THEN
      PTC_ROAD(JLOOP,:)= BDD%XDESC_TC_ROAD(IINDEX,:)
    ENDIF
    IF (PRESENT(PD_ROAD)) THEN
      PD_ROAD(JLOOP,:)= BDD%XDESC_D_ROAD(IINDEX,:)
!
    IF (PRESENT(PALB_ROOF)) THEN
      PALB_ROOF(JLOOP)=BDD%XDESC_ALB_ROOF(IINDEX)
    ENDIF
    IF (PRESENT(PEMIS_ROOF)) THEN
      PEMIS_ROOF(JLOOP)=BDD%XDESC_EMIS_ROOF(IINDEX)
    ENDIF
    IF (PRESENT(PHC_ROOF)) THEN
      PHC_ROOF(JLOOP,:)= BDD%XDESC_HC_ROOF(IINDEX,:)
    ENDIF
    IF (PRESENT(PTC_ROOF)) THEN
      PTC_ROOF(JLOOP,:)= BDD%XDESC_TC_ROOF(IINDEX,:)
    ENDIF
    IF (PRESENT(PD_ROOF)) THEN
      PD_ROOF(JLOOP,:)= BDD%XDESC_D_ROOF(IINDEX,:)
!
! Wall
!
    IF (PRESENT(PALB_WALL)) THEN
      PALB_WALL(JLOOP)=BDD%XDESC_ALB_WALL(IINDEX)
    ENDIF
    IF (PRESENT(PEMIS_WALL)) THEN
      PEMIS_WALL(JLOOP)=BDD%XDESC_EMIS_WALL(IINDEX)
    ENDIF
    IF (PRESENT(PHC_WALL)) THEN
      PHC_WALL(JLOOP,:)= BDD%XDESC_HC_WALL(IINDEX,:)
    ENDIF
    IF (PRESENT(PTC_WALL)) THEN
      PTC_WALL(JLOOP,:)= BDD%XDESC_TC_WALL(IINDEX,:)
    ENDIF
    IF (PRESENT(PD_WALL)) THEN
      PD_WALL(JLOOP,:)= BDD%XDESC_D_WALL(IINDEX,:)
!
! Position of isolation layers
!
    IF (PRESENT(NISOROOFPOS)) THEN
       NISOROOFPOS(JLOOP) = BDD%NDESC_ISOROOFPOS(IINDEX)
    ENDIF
     IF (PRESENT(NISOWALLPOS)) THEN
        NISOWALLPOS(JLOOP) = BDD%NDESC_ISOWALLPOS(IINDEX)
     ENDIF
!
! Floor
!
    IF (PRESENT(PHC_FLOOR)) THEN
      PHC_FLOOR(JLOOP,:)= BDD%XDESC_HC_FLOOR(IINDEX,:)
    ENDIF
    IF (PRESENT(PTC_FLOOR)) THEN
      PTC_FLOOR(JLOOP,:)= BDD%XDESC_TC_FLOOR(IINDEX,:)
    ENDIF
    IF (PRESENT(PD_FLOOR)) THEN
      PD_FLOOR(JLOOP,:)= BDD%XDESC_D_FLOOR(IINDEX,:)
    IF (PRESENT(PHC_MASS)) THEN
       PHC_MASS(JLOOP,:)= BDD%XDESC_HC_MASS(IINDEX,:)
    ENDIF
    IF (PRESENT(PTC_MASS)) THEN
       PTC_MASS(JLOOP,:)= BDD%XDESC_TC_MASS(IINDEX,:)
    ENDIF
    IF (PRESENT(PD_MASS)) THEN
       PD_MASS(JLOOP,:)= BDD%XDESC_D_MASS(IINDEX,:)
    ENDIF
    IF (PRESENT(PISMASS)) THEN
       PISMASS(JLOOP) = BDD%XDESC_ISMASS(IINDEX)
    IF (PRESENT(PN50)) THEN
       PN50(JLOOP) = BDD%XDESC_N50(IINDEX)
    ENDIF
!
    IF (PRESENT(PGR)) THEN
      PGR(JLOOP) = BDD%XDESC_GR(IINDEX)
!
    IF (PRESENT(PU_WIN)) THEN
       PU_WIN(JLOOP) = BDD%XDESC_U_WIN(IINDEX)
    IF (PRESENT(PSHGC)) THEN
       PSHGC(JLOOP) = BDD%XDESC_SHGC(IINDEX)
    IF (PRESENT(PSHGC_SH)) THEN
       PSHGC_SH(JLOOP) = BDD%XDESC_SHGC_SH(IINDEX)
    ENDIF
    !
    IF (PRESENT(PSHADEARCHI)) THEN
       PSHADEARCHI(JLOOP) = BDD%XDESC_SHADEARCHI(IINDEX)
    IF (PRESENT(PISMECH)) THEN
       PISMECH(JLOOP) = BDD%XDESC_ISMECH(IINDEX)
    IF (PRESENT(PMECHRATE)) THEN
       PMECHRATE(JLOOP) = BDD%XDESC_MECHRATE(IINDEX)
    ENDIF
    !
    IF (PRESENT(PGREENROOF)) THEN
      PGREENROOF(JLOOP) = BDD%XDESC_GREENROOF(IINDEX)
    ENDIF
    !
    IF (PRESENT(PEMIS_PANEL)) THEN
      PEMIS_PANEL(JLOOP) = BDD%XDESC_EMIS_PANEL(IINDEX)
    ENDIF
    !
    IF (PRESENT(PALB_PANEL)) THEN
      PALB_PANEL(JLOOP) = BDD%XDESC_ALB_PANEL(IINDEX)
    ENDIF
    !
    IF (PRESENT(PEFF_PANEL)) THEN
      PEFF_PANEL(JLOOP) = BDD%XDESC_EFF_PANEL(IINDEX)
    ENDIF
    !
    IF (PRESENT(PFRAC_PANEL)) THEN
      PFRAC_PANEL(JLOOP) = BDD%XDESC_FRAC_PANEL(IINDEX)
!      ----------------------------------------------------
! Architectural parameters not read from table
!      ---------------------------------------------------
!
    IF (PRESENT(PCAP_SYS_HEAT)) THEN
      PCAP_SYS_HEAT(JLOOP) = 100.
    ENDIF
!
    IF (PRESENT(PCAP_SYS_RAT)) THEN
      PCAP_SYS_RAT(JLOOP) = 90.
    ENDIF
!
    IF (PRESENT(PT_ADP)) THEN
      PT_ADP(JLOOP) = 285.66
    ENDIF
!
    IF (PRESENT(PM_SYS_RAT)) THEN
      PM_SYS_RAT(JLOOP) = 0.0067
    ENDIF
!
    IF (PRESENT(PT_SIZE_MAX)) THEN
      PT_SIZE_MAX(JLOOP) = 301.95
    ENDIF
!
    IF (PRESENT(PT_SIZE_MIN)) THEN
      PT_SIZE_MIN(JLOOP) = 268.96
    ENDIF
!
    IF (PRESENT(PFLOOR_HEIGHT)) THEN
      PFLOOR_HEIGHT(JLOOP) = 2.9
    ENDIF
!
    IF (PRESENT(PROUGH_ROOF)) THEN
      PROUGH_ROOF(JLOOP) = 1.52
    ENDIF
!
    IF (PRESENT(PROUGH_WALL)) THEN
      PROUGH_WALL(JLOOP) = 1.52
    ENDIF

!
END DO
!
DEALLOCATE(ILIST)
!
! ###########################################################
! Initialisation of behavioural characteristics
! When using the building description files, it is possible
! to simulate with 1 or 6 compartments
! For 6-compartments-case, the compartments are defined as follows
! - (1): FORT CRE   (low design temperature, if applicable)
! - (2): FAIBLE CRE (high design temperature, if applicable)
! - (3): Mean between FORT CRE and FAIBLE CRE (if applicable)
! - (4): non-heated fraction of the building
! - (5): COMMERCIAL fraction (if applicable)
! - (6): TERTIARE   fraction (if applicable)
!
! For the 1-compartment-case, the input values are averaged
! to represent the variety of behaviours as good as possible
!
! More details can be found in Schoetter et al. (2017), GMD.
!
! ###########################################################
!
! Initialisation of the fraction of compartments
!
DO JLIST=1,SIZE(DTT%NPAR_USETYPE)
   !
   IF (PRESENT(PFRACOMP)) THEN
      !
      IF (SIZE(PFRACOMP,2).EQ.1) THEN
         !
         PFRACOMP(JLIST,1) = 1.0
         !
      ELSEIF (SIZE(PFRACOMP,2).EQ.6) THEN
         !
         IF (DTT%NPAR_USETYPE(JLIST).EQ.BDD%NDESC_POS_USE_HAC) THEN
            !
            ! For main use = COLLECTIVE housing, a non-heated fraction,
            ! a COMMERCIAL and TERTIARY fraction and 3 residential
            ! compartments with 3 different heating design temperatures are considered.
            ! The non-heated fraction related to this specific building archetype
            ! It will be used to normalise the commercial and office fraction
            !
            PFRACOMP(JLIST,4) = BDD%XDESC_FNOHEAT_AVG(DTT%NPAR_USETYPE(JLIST)) + &
               BDD%XDESC_FNOHEAT_MOD(DTT%NPAR_USETYPE(JLIST))*(2*DTT%XPAR_CRE_APPT(JLIST)-1)
            !
            PFRACOMP(JLIST,5) = DTT%XPAR_FRACCOM(JLIST)*(1.0-PFRACOMP(JLIST,4))
            PFRACOMP(JLIST,6) = DTT%XPAR_FRACTER(JLIST)*(1.0-PFRACOMP(JLIST,4))
            !
            PFRACOMP(JLIST,4) = ( 1.0 - DTT%XPAR_FRACNHE(JLIST) - DTT%XPAR_FRACIND(JLIST) ) * ( &
                 BDD%XDESC_FNOHEAT_AVG(DTT%NPAR_USETYPE(JLIST)) + &
                 BDD%XDESC_FNOHEAT_MOD(DTT%NPAR_USETYPE(JLIST)) * (2*DTT%XPAR_CRE_APPT(JLIST)-1) ) + &
                 DTT%XPAR_FRACNHE(JLIST) + DTT%XPAR_FRACIND(JLIST)
            !
            PFRACOMP(JLIST,1) = (1.0 - PFRACOMP(JLIST,4) - PFRACOMP(JLIST,5) - PFRACOMP(JLIST,6)) * &
                 (DTT%XPAR_CRE_APPT(JLIST)  * BDD%XDESC_FLDT(BDD%NDESC_POS_HAC_FORTCRE) + &
             (1.0-DTT%XPAR_CRE_APPT(JLIST)) * BDD%XDESC_FLDT(BDD%NDESC_POS_HAC_FAIBCRE))
            !
            PFRACOMP(JLIST,2) = (1.0 - PFRACOMP(JLIST,4) - PFRACOMP(JLIST,5) - PFRACOMP(JLIST,6)) * &
                 (DTT%XPAR_CRE_APPT(JLIST)  * BDD%XDESC_FHDT(BDD%NDESC_POS_HAC_FORTCRE) + &